Parameter

Default value

Definition

 

 

 

Level of Data

Medium

This parameter configures how much data is returned to

Returned

 

Insight Manager.

 

 

None returns no data.

 

 

Low returns the current board status and the board type

 

 

(RILOE II).

 

 

Medium returns the board status, the board type, and the

 

 

serial number.

 

 

High returns the board status, the board type, the serial

 

 

number and several other pieces of information.

 

 

 

View XML Reply

N/A

This parameter displays the XML reply sent to Insight

 

 

Manager. This parameter only displays when you use

 

 

Internet Explorer.

SNMP alerts and settings

In the Administration>SNMP Settings section, you can enable, disable, and test SNMP alerts. SNMP alerts are forwarded from the host server and RILOE II to an Insight Manager console. The two types of alerts are:

Host OS Generated SNMP Traps—The Insight Management agents provided for each supported network operating system generate these alerts. These agents must be installed on the host server to receive these alerts. Alerts are sent to Insight Manager clients on the network and forwarded asynchronously by RILOE II to users that have been configured to receive them.

Remote Insight Board Alerts—These alerts are generated when RILOE II detects conditions that are independent of the host server operating system. These alerts can be Insight Manager SNMP traps or pager alerts. Alerts include major events, such as a host server power outage or host server reset, and RILOE II events, such as a disconnected keyboard cable or an unauthorized login attempt.

To enable alerts:

Using the RILOE II 31