2CONNECT ELECTRICAL
CORD
To place electrical receptacle, see Electrical Receptacle Location diagram in this manual.
$FFHVV
FRYHU
Range has been grounded at the factory to the center (nickel plated) terminal of the terminal block in accordance with the National Electric Code. When a separate ground is required by local code, disconnect the grounding strap from the terminal block. Ground frame by connecting a grounding wire to range frame using the grounding strap and screw, as shown below, removed from the grounding strap.
3-wire or 4-wire Plug Connection
1.Remove access cover from rear of range.
2.Use a strain relief (not supplied) and insert end of power cord (not supplied) through power supply hole.
3.
4.Unscrew and use top hex nut to attach the power cord wires to the terminal block as follows:
•Red wire to “L1” terminal.
•Black wire to “L2” terminal.
•White wire to Neutral terminal.
5.Tighten all hex nuts and reinstall access cover removed in step 1.
ZLUH&RUG,QVWDOOHGZLUH&RUG,QVWDOOHG
| 1HXWUDO |
/ | / |
| |
| / |
5HG | 5HG |
:KLWH | :KLWH |
| |
| %ODFN |
Converting 3-Wire to 4-Wire Power Cord
1.Remove access cover from rear of range.
2.Remove bottom strain relief screw and retain for further use.
3.Remove hex nuts from terminal block and retain for further use.
4.Remove all
5.To install the
1HXWUDO
/
*URXQG
VWUDS
*URXQG
*URXQG ZLUH VFUHZ
RS2320006 Rev. 0 |