Genesis Control Testing Information
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.
Mylar Overlay⎯KRC |
|
|
|
|
|
|
|
| OVEN |
| COOK |
| CLEAN | OFF |
TIMER |
| WM | ||
ON OFF | CLEAN |
|
|
|
TIME |
| BROIL |
| |
|
|
| ||
|
|
|
| |
| OVEN |
|
|
|
| LIGHT |
|
| |
RECALL | START |
|
|
|
OVEN TEMP | COOK |
|
| BAKE |
CLEAN |
|
| ||
CLOCK |
|
| ||
|
|
| ||
| PREHEAT | LOCKED | PUSH TO TURN | |
Illustration | Component | Test Procedure |
| Results |
|
| Genesis electronic | Measure voltage at terminals |
|
|
| range control | J2−E7 (L1) and E2 (NEU) | 120 VAC should be indicated, verifying |
|
|
|
| voltage to control. |
|
| On | Relay drive requirements |
|
|
| light will blink for | Bake⎯BA to L2 | 240 VAC, if not replace control. |
|
| approximately 25 | Broil ⎯BR to L2 | |
|
| 240 VAC, if not replace control. | ||
|
| seconds, while | Bake | |
|
| 75% bake element 25% broil element | ||
|
| control is verifying | Broil | |
| J2 | 100% broil element | ||
| lock latch position. | Clean | ||
|
| |||
| E5 |
| Stage 1 | Time controlled 60 minutes 100% broil |
| On power up, if | Stage 2 | ||
E7 | 50% bake element and 50% broil element | |||
|
| sensor has failed. | Time (Adjustable) | |
| E3 | 2 hours minimum to 4 hours maximum | ||
|
| No F−Code will be |
| |
| E4 | Failure codes: |
| |
| displayed. |
| ||
E2 |
|
| ||
| No oven functions | Verify voltage to control. | ||
| E1 | |||
| will start. |
| If no voltage is present, check wiring. | |
|
|
| ||
|
|
|
| If voltage is present, replace control. |
|
| 1 | Check sensor resistance and wiring. | |
| J1 | PIN |
| Replace control if sensor and wiring are |
|
|
| good. | |
|
|
|
| |
|
|
| Open or Shorted | Check sensor resistance and wiring. |
|
|
|
| Replace sensor, if wiring is good. |
Check latch switch and associated wiring. | |
Temperature Calibration | Turn oven control to OFF position. |
| Press and hold both slew pads for 5 sec. |
| Use slew pads to adjust temp setting. |
| After 5 sec. of no input the mode is exited. |