Component Testing Information
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.
Refer to Technical Sheet or Parts Manual for replacement components specifications.
Illustration | Component | Test Procedure |
| Results |
|
| Oven light socket | Remove one wire from receptacle |
|
|
|
|
| and test resistance of terminals. | Indicates continuity with bulb screwed in. | ||
|
| Measure voltage at oven light | 120 VAC, see wiring diagram for terminal | ||
|
|
| identification. |
|
|
|
|
| If no voltage is present at oven light, | ||
|
|
| check wiring or light switches. | ||
| Oven indicator light | Remove one lead from switch | Switch closed: 0 Ω |
| |
| and | terminal and measure resistance | Switch open: | Infinite resistance | |
| Surface indicator light | across terminals. |
|
|
|
|
| Measure voltage at indicator light | If voltage is present and light does not | ||
|
|
| operate. Replace light. |
| |
|
|
| If no voltage is present at indicator light | ||
|
|
| check wiring. |
|
|
| Rocker switch | Measure continuity of switch |
|
|
|
|
| positions: |
|
|
|
|
| Closed | Continuity, if not replace. |
| |
|
| Open | Infinite, if not replace. |
| |
| Ribbon radiant | Remove one wire lead from element | Continuity, if not replace. |
| |
| elements, limiters are | and measure resistance of the | 1200W: 44 to 49 Ω Approximately | ||
| not replaceable. | element. | 1500W: 36 to 40 Ω Approximately | ||
|
|
| 2000W: 26 to 30 Ω Approximately | ||
|
| Verify supply voltage | 2500W: 20 to 23 Ω Approximately | ||
|
| 240 VAC |
|
| |
| Infinite switch | Remove wiring from terminals H1 and | Time On | Time Off | |
|
| H2. Connect Volt ohms meter to | LO | 5% | 95% |
|
| H1 and H2. | MED | 50% | 50% |
|
|
| HI | 100% | 0% |
|
| Measure the following for voltages at |
|
|
|
|
| LO, MED, HI: |
|
|
|
|
| H1 to H2 | 240 VAC, if not replace switch. | ||
| Control limit | Normally Closed |
|
|
|
|
| Verify proper operation. |
|
|
|
|
| Closed | Continuity |
|
|
|
| Open | Infinite |
|
|
|
|
| If open at room temperature, replace. | ||
| Bake element | Disconnect wire leads to element and | Continuity, approximately 20 Ω, | ||
|
| measure resistance of terminals. | if not replace. |
|
|
|
| Measure voltage at bake element | 240 VAC, see wiring diagram for terminal | ||
|
|
| identification. |
|
|
|
|
| If no voltage is present at bake element | ||
|
|
| check wiring. |
|
|
| Broil element | Disconnect wire leads to element and | Continuity, approximately 19 Ω, | ||
|
| measure resistance of terminals. | if not replace. |
|
|
|
| Measure voltage at broil element | 240 VAC, see wiring diagram for terminal | ||
|
|
| identification. |
|
|
|
|
| If no voltage is present at broil element | ||
|
|
| check wiring. |
|
|
| Oven temperature | Measure resistance | Approximately 1100 Ω at room | ||
| sensor |
| temperature 75°F. |
| |
| Auto latch assembly | Motor switch | COM − N.O.⎯ continuity |
| |
|
| Unlocked |
| ||
|
| Locked | COM − N.O.⎯ open |
| |
|
| Door switch |
|
|
|
|
| Door closed | COM − N.C.⎯ continuity |
| |
|
| Door open | COM − N.C.⎯ open |
|
RS2320006 Rev. 0 | 8 |