3ware Disk Manager (3DM 2)
Warning: Removing or adding drives which are not in hotswap carriers can result in a system hang or may even damage the system and the drive.
In
If new drives do not have any data indicating they were previously part of a 3ware RAID configuration, they will appear in the Available Drives list.
In addition, if there is a unit with the status Inoperable before a rescan (for example, a RAID 5 unit missing 2 or more drives), and a rescan finds drives that complete the unit, the inoperable unit will become a valid unit.
Note: In
8000 will again see the drives as a valid unit.
Unit Maintenance
The Unit Maintenance section of the page lists all existing units on the current controller, and displays summary information about them.
The top row shows information about the unit, while subsequent rows show summary information about each drive in the unit.
Unit Information
Unit Number. The unit number assigned to the unit by the firmware. Unit numbers for 9000 series are in sequential order. Unit numbers for the 7/8000 series will begin with the lowest port number of the unit. Use the checkbox next to the unit to select a unit before clicking one of the task buttons.
60 | 3ware 9000 Series Serial ATA RAID Controller User Guide |