3ware Disk Manager (3DM 2)
Two
Upgrade UDMA mode. This test checks the speed at which data transfer to drives is occurring, to see if the UDMA mode can be increased. (If you are already running at the fastest UDMA mode, then this
The UDMA mode can become downgraded in the event that cable CRC errors are encountered, requiring multiple retries to read sectors. In severe cases, the UDMA mode may be downgraded from ATA 150 to ATA 133, to ATA 100, to 66, to 33.
This check is also done every time the system is booted. UDMA mode does not apply to SATA.
Check SMART Thresholds. This test checks to see whether SMART thresholds have been exceeded.
The SMART thresholds indicate when a drive is likely to fail, based on the number of errors that have been recorded through SMART
If any of the disk drives have detected a “threshold exceeded” condition, then an AEN is logged to the 3DM Alarms page. Moreover, if anything unusual is found during any
58 | 3ware 9000 Series Serial ATA RAID Controller User Guide |