Chapter 2: Connection and Setup of the ADCC1100

This chapter describes the power and data connections between the ADCC1100 keyboard and the switching system being used.

Supplied Equipment

The ADCC1100 is supplied with the following equipment and accessories:

Two seven foot, MP-CBL connection cables

One MP-KMI wall-mount keyboard matrix interface

UK cable and plug, USA cable and plug, mainland European cable and plug

MP-PSU power supply unit

One Administrator's Smart Card

The power supply is connected to the jack connector of the MP-KMI network access point. The power supply must be a UL listed, Class 2 type.

Setting the Jumpers for the MP-KMI

The MP-KMI contains six jumper links that must be configured according to figure 2.1. Access to the jumpers is obtained by removing the screw holding the cover in place. The table shows the connectivity of the links in the MP-KMI. For most purposes the links should be left in the 2 and 3 position and this is the default factory setting. The KMI performs a RX / TX cross over between the keyboard and matrix RJ45 connectors in this mode. To remove the cross over (which may be required in certain situations), change links 3 and 4 from the default 2 and 3 linked position, to the 1 and 2 position.

Link

Matrix RJ45 pin

1 and 2 Linked

 

2 and 3 Linked

 

 

 

 

 

Lk1

2

+12v

 

Gnd

Lk2

3

Kbd Pin 3

 

n/c

Lk3

4

Kbd Pin 4

 

Kbd Pin 5

Lk4

5

Kbd Pin 5

 

Kbd Pin 4

Lk5

6

Kbd Pin 6

 

n/c

Lk6

8

+12 v

 

Gnd.

 

 

 

 

 

 

 

GND

Tx

Rx

LK6

LK5

LK3 LK4

LK1 LK2

1

2

3

1

2

3