Keyboard Installation and Operation

5.Press the QUICKSITE CONFIG soft key. The Quicksite configuration menu is displayed (figure 5.2).

Site

Site

Start

End

 

Home

Up

1

1

256

H

Up

 

 

 

2

257

500

 

 

Site

3

512

675

 

Home

4

1024

1200

 

Down

 

Down

 

5

2315

2540

 

 

 

6

3000

3100

 

 

Start

7

5100

5250

 

Read

Cam

8

6500

6550

 

SC

 

9

- - - -

- - - -

 

 

End

 

 

 

 

Prog

Cam

 

 

 

 

SC

Operator

Program Mode

 

Macros

Figure 5.2: Quicksite Configuration Menu

In this menu, configure the different sites in the system using the following procedures:

Configuring Satellite Sites

To configure the settings for satellite sites:

1.Using the SITE UP and SITE DOWN soft keys, move the arrow cursor to the site which is to edited.

2.To specify the pseudo number of the first camera at this site, use the numerical keys to enter the required camera number and press the START CAM soft key.

3.To specify the pseudo number of the last camera at this site, use the numerical keys to enter the required camera number and press the END CAM soft key.

Important Note: The pseudo numbers programmed to the keyboard must match the pseudo numbers programmed to each individual matrix site.

4.Repeat steps 1 to 3 to configure each satellite site. Up to nine sites can be included. Camera numbers from site to site do not need to be sequential (as illustrated in the figure above), but the camera numbers cannot overlap.

To clear a site, move the cursor to the required site, enter a 0 on the numerical keypad and press either the START CAM or END CAM soft key.

5.Once the camera numbering has been configured, it is necessary to specify a home site for the keyboard in use. The home site is the site to which the keyboard is directly connected.

To specify the keyboard's home site, use the HOME UP and HOME DOWN soft keys to move the H marker to the required site.

6.To store the settings to a smart card, press the PROG SC soft key.

7.The keyboard will display the message "Please Replace Smart Card". Insert the smart card to be programmed and wait until the process is completed.