Keyboard Installation and Operation
Appendix A: Monitor Arming Commands
Monitors are armed for alarm call up with codes that specify the following three parameters:
1.The display method (single, dual, or block monitors).
2.The queuing method (sequence or hold).
3.The clearance method (instant, auto, or manual).
To arm a monitor with an ADCC1100 keyboard:
1.Call the monitor to be armed.
2.Press the PROGRAM MODE tab key.
3.Enter the monitor arming code number (see table).
4.Press the F2 soft key.
A keyboard operator can also program any monitor armed for instant or auto clearance, for clearance via manual override. Manual override is enabled or disabled after the arming code is programmed. If enabled, an "A" will appear after the
When using the AD1024 matrix switcher/controller system, monitors can be armed through system setup software with a PC interface, or through the AD1024 embedded software with an ADCC1100 keyboard. Following is a table of monitor arming codes and the commands that enable the codes.
Monitor Arming Code | Monitor Acronym | Command Sequence |
|
|
|
Display Arming Status | see entries below | 300, F2 |
Single, Sequence, Instant | SSI | 301, F2 |
Single, Sequence, Auto | SSA | 302, F2 |
Single, Sequence, Manual | SSM | 303, F2 |
Single, Hold, Instant | SHI | 304, F2 |
Single, Hold, Auto | SHA | 305, F2 |
Single, Hold, Manual | SHM | 306, F2 |
Block, Sequence, Instant | BSI | 307, F2 |
Block, Sequence, Auto | BSA | 308, F2 |
Block, Sequence, Manual | BSM | 309, F2 |
Block, Hold, Instant | BHI | 310, F2 |
Block, Hold, Auto | BHA | 311, F2 |
Block, Hold, Manual | BHM | 312, F2 |
Dual, Hold, Instant | DHI/DSI* | 313, F2 |
Dual, Sequence, Instant |
|
|
Dual, Hold, Auto | DHA/DSA* | 314, F2 |
Dual, Sequence, Auto |
|
|
Dual, Hold, Manual | DHM/DSM* | 315, F2 |
Dual, Sequence, Manual |
|
|
Disarm Monitor |
| 316, F2 |
Enable Monitor Override |
| 317, F2 |
Disable Monitor Override |
| 318, F2 |
*In dual display applications, the first
43