Vicon Command Summary

The following table lists the Vicon controller key sequence to control the indicated SpeedDome Ultra VII functions.

If you want to …

 

 

Use …

 

Set Auto Iris ON/OFF

 

 

A/I Toggles state

 

(LED indicates Auto Iris state: ON = AUTO)

 

 

 

 

 

Set Auto Focus ON/OFF

 

 

Press and Hold L-Spd

 

(LED indicates Auto Focus state: ON = AUTO)

 

 

A/P Toggles state

 

 

 

 

 

 

 

 

 

 

Goto Presets

 

 

Run/Pgm switch to RUN

 

 

 

 

Enter 1-79 Enter

 

Program Presets

 

 

Run/Pgm switch to PGM

 

 

 

 

Enter 1-79 Enter

 

Run PEEL Pattern and Repeat

 

 

AUX5

 

 

 

 

 

 

Rotate dome 180° (“Flip”)

 

 

AUX6

 

Start Pattern 1-3 Definition

 

 

Run/Pgm switch to PGM

 

 

 

 

Enter 80-82 Enter

 

End Pattern Definition

 

 

Run/Pgm switch to PGM

 

 

 

 

Enter 86 Enter

 

Review Pattern

 

 

Run/Pgm switch to PGM

 

 

 

 

Enter 87 Enter

 

Accept Pattern

 

 

Run/Pgm switch to PGM

 

 

 

 

Enter 88 Enter

 

Run Pattern 1-3

 

 

Run/Pgm switch to RUN

 

 

 

 

Enter 80-82 Enter

 

Repeat Pattern 1-3

 

 

Run/Pgm switch to RUN

 

 

 

 

Enter 83-85 Enter

 

Set Pattern to Peel

 

 

Enter 89 Enter

 

 

 

 

 

 

Vphase Dome

 

 

Run/Pgm switch to PGM

 

Note: The A/I LED blinks indicating that you are in the vphase

 

 

Enter 93 Enter

 

 

 

 

 

mode. Enter key sequence again to turn vphase adjustment off.

 

 

Pan Right to increment

 

The A/I LED stops blinking and indicates Auto Iris State.

 

 

Pan Left to decrement

 

 

 

 

 

 

 

 

 

 

Start Dome Configuration Menu

 

 

Enter 94 Enter

 

See Operating the Dome Configuration Menu on page F–3.

 

 

 

 

 

 

 

 

 

 

Turn IR Mode On

 

 

Run/Pgm switch to PGM

 

 

 

 

Enter 95 Enter

 

Turn IR Mode Off

 

 

Run/Pgm switch to PGM

 

 

 

 

Enter 96 Enter

 

Reset Dome

 

 

Run/Pgm switch to PGM

 

 

 

 

Enter 97 Enter

 

F–2

SpeedDome Ultra VII Operator's Manual