Performance Notes

When selecting a dome, a 3- to 5-second delay is necessary for the Panasonic multiplexer to properly identify the dome type. If the dome is moved before the interrogation is complete, the controller recognizes the dome as a “single speed” dome. Once the dome stops moving and the interrogation completes, the normal 8 speed settings are available.

Address Setting

The dome must have the correct address setting to operate with Panasonic UTC protocol. Set the dome address switches to 890.

Programming Presets

You must use the Dome Configuration Menu to program Presets. Up to 64 Presets may be programmed.

Note: This procedure has been verified using the following equipment:

WJ-SX550 Multiplexer

WV-CU550A Controller

1.Select the monitor and camera number assigned to the Speed Dome Ultra VII camera dome.

2.Use the arrow keys on the controller to scroll to the Camera Setup Menu (D4).

3.Press F1 (On) key to display the Dome Configuration Menu.

4.Use the joystick to move the highlight to Alarms/Areas/Home/Presets/PZ. Press Set to select.

ALARMS/AREAS/HOME/PRESETS/PZ

SET ALARM ACTIONS

SET ALARM STATES

SET HOME POSITION

SET NORTH POSITION

AREA BOUNDARIES

PRIVACY ZONES

PRESETS

SCAN LIMITS

EXIT

D–4

SpeedDome Ultra VII Operator's Manual