Configuring Alarm Actions
I M P O R T A N T
When operating on Manchester networks, the dome can be programmed to respond to any of the four available alarm inputs. However, the dome cannot transmit alarm input states to the host controller. If transmitting the alarm state to the host controller is required, the alarm device must be wired directly to the host controller.
The dome provides four alarm inputs. By connecting alarm
When Set Alarm Actions is selected from Alarms/Areas/Home/Presets/PZ screen, the following screen appears:
SET ALARM ACTIONS
| INTERNAL ALARMS | ||
INPUT NO. |
| ACTION |
|
1 |
|
|
|
| NO ACTION |
| |
2 |
| PRESET | |
3 |
| PATTERN | |
4 |
| NO ACTION |
|
SEND INPUTS TO HOST? YES / NO
EXIT
Use this screen to assign a preset or pattern to occur whenever the alarm's input state changes from normal to abnormal. You may also choose to have no action occur when the alarm's input state changes.
Alarms can be processed internally by the dome, externally by the controller, or both. You may choose to send changes in the input state to the host controller. If the changes in input state are sent to the host controller, the host actions have higher priority than the associated dome actions.
Note: An active internal alarm only resets when the input state changes to “normal.” A manual reset is not available.
Configuring Alarms, Areas, Home, Privacy Settings, Presets, and Scan Limits |