Exiting the Configuration Utility
Under SensorNet,
•If you want to keep the changes you made, move the highlight bar to Exit and Save Changes, and select. The utility closes.
•If you want to exit without making changes, move the highlight bar to Quit Without Saving, and select. The following prompt appears on the screen:
Data Not Saved. Quit Anyway?
No
Press Zoom to display the options.
•To cancel the changes, select Yes.
•To keep the changes, select No. If you choose No, the Dome Configuration Menu is displayed. Press Focus to accept the displayed option.
I M P O R T A N T
The following settings do not restore when selecting Quit Without Saving from the Dome
Configuration Menu: Area Boundaries and AGC/Shutter Limit.
Accessing the Quick Set Menu
SpeedDome Ultra VII provides a Quick Set Menu for commonly used features and functions when used with compatible controllers. This allows you to change or activate features without starting the dome configuration menu.
0TOGGLE QUICK SET MENU
1DOME CONFIG MENU
2AUTO IRIS/AUTO FOCUS
3FLIP
4PEEL PATTERN
15SMOOTH SCAN
16STEPPED SCAN
17RANDOM SCAN
20 DOME INFORMATION
To access a feature on the menu, enter the number and press the Quick Set button (varies by controller). The following provides a description of the available options.