Appendix B

I/O Interface Board

Table B-3 lists the interface between Utility 2a (J5) and the other connectors/devices on the I/O Board.

Table B-3. Utility 2a Interface Pin/Signal Descriptions (J5)

J5

Signal

OnBoard

Description

Pin #

 

Pin #

 

1

STB*

J12-1

Parallel Strobe* – Output used to strobe data into the printer. I/O pin

 

 

 

in ECP/EPP mode.

 

NC

J11-14

Not connected (DS0 – Drive Select 0)

2

AFD*

J12-2

Parallel Auto Feed – This is a Request signal sent to the printer to

 

 

 

automatically feed one line after each line is printed.

 

DEN0

J11-2

Floppy Drive Density Select Bit 0 – This signal indicates a low

 

 

 

(250/300 kbps) or high (500 kbps) data rate has been selected.

3

PD0

J12-3

Parallel Data 0 – These signals (0 to 7) provide the parallel port data

 

 

 

to the printer.

 

INDEX*

J11-8

Floppy Index – Sense detects the head is positioned over the

 

 

 

beginning of a track

4

ERR*

J12-4

Parallel Error – This is a Status output signal from the printer. A Low

 

 

 

State indicates an error condition on the printer.

 

HDSel*

J11-32

Floppy Head Select – Selects FDD side for Read/Write operations

 

 

 

(0 = side 1, 1 = side 0)

5

PD1

J12-5

Parallel Data 1 – Refer to PD0, pin 3, for more information.

 

TRK0

J11-26

Floppy Track 0 – Sensor detects the head is positioned over track 0.

6

PInit*

J12-6

Parallel Initialize – This signal used to Initialize printer. Output in

 

 

 

standard mode, I/O in ECP/EPP mode.

 

DIR*

J11-18

Floppy Direction – Direction of floppy head movement

 

 

 

(0 = inward motion, 1 = outward motion).

7

PD2

J12-7

Parallel Data 2 – Refer to PD0, pin 3, for more information.

 

WrtPrt*

J11-28

Floppy Write Protect – Senses the diskette is write protected.

 

 

 

 

8

SLIn*

J12-8

Parallel Select In – This signal used to select the printer. I/O pin in

 

 

 

ECP/EPP mode.

 

STEP*

J11-20

Floppy Step – Low pulse for each track-to-track movement of the head.

9

PD3

J12-9

Parallel Data 3 – Refer to PD0, pin 3, for more information.

 

RData*

J11-30

Floppy Read Data – Raw serial bit stream from the drive for read

 

 

 

operations.

10

SMB_

U3-11

SMBus Alert – This pin receives signals from thermal monitor (U3).

 

Alert

J10-3

SMBus Alert – This pin sends/receives to/from external devices.

 

 

11

PD4

J12-11

Parallel Data 4 – Refer to PD0, pin 3, for more information.

 

DskChg*

J11-34

Floppy Disk Change – Senses the drive door is open or the diskette

 

 

 

has been changed since the last drive selection.

12

GND

GND

Ground

13

PD5

J12-13

Parallel Data 5 – Refer to PD0, pin 3, for more information.

 

 

 

 

14

GND

GND

Ground

15

PD6

J12-15

Parallel Data 6 – Refer to PD0, pin 3, for more information.

 

NC

J11-10

Not Connected (MTR0 – Motor Control 0)

 

 

 

 

16

GND

GND

Ground

26

QuickStart Guide

CoreModule 800

Page 30
Image 30
Ampro Corporation PCI-104 quick start Signal OnBoard Description Pin #