Performing the Self Test

1.Power off the printer.

2.Make sure that 4 inch wide media is installed. The Self-test will print the maximum width of the installed label.

3.Press and hold the FEED/Config button.

4.Power on the printer.

5.Release the FEED/Config button when:

a.FM 4402: The printer begins feeding labels.

b.FM 4602 and FM 4603: The message “SELF TESTING…” is displayed on the LCD.

6.The following the occur depending upon the emulation installed into the printer:

PPLA emulation:

The printer will print a configuration page then feed to the

 

first print position on the next label.

PPLB emulation:

The printer will print a configuration page, feeds one line and

 

then enter into its Hexadecimal print mode. To exit the

 

Hexadecimal mode press the CANCEL/Reset button then

 

press the FEED/Config button to go to the first print position

 

on the next label.

7.The following information will be printed on this report.

-Font list

-DIP switch settings (FM4602 and FM4603 only)

-Hardware configuration and status

-Label parameters

-Firmware version

Note: The following figures are examples of self-tests run on FM4402, and FM4602/4603 with both PPLA and PPLB emulation's installed. The feature setting on your printer may be different depending upon options selected.

Note: Print samples printed on the FM4602 and FM4603 are similar.