NXC-I/O10 Input/Output Control Card
The
The I/Os on this card are not dry closure; they are electronic switches that float at 5V when Off. Therefore, they should not be expected to work in situations that require true dry contact (or dry closure).
The I/Os do work with AMX PC1, PC2, UPC20 and UPC20+.
SW/VO Jumpers (J1 - J5)
SW/VO Jumpers (J16 - J30)
FIG. 4 NXC-I/O10 Control card
Specifications
NXC-I/O10 Specifications
Power Requirements | 180 mA @ 12 VDC |
|
|
Operation | I/O |
|
|
Status LEDs (1 per channel | Yellow LEDs light to show ON status activity |
|
|
Modes: |
|
Switch | Senses switch or relay contact closures or provides a |
Voltage |
|
Senses high- and | |
|
|
Voltage clamp settings: |
|
12 V mode (default) | Clamps any voltage connected to I/O ports |
VO mode |
|
Use for connections that will draw more than 12 V. | |
|
|
Connections/wiring | Two |
|
|
NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide | 11 |
|
|