AMX nxc manual Ctof, Cton

Models: nxc

1 46
Download 46 pages 61.34 Kb
Page 23
Image 23

 

NXC-IRS4 4-Port IR/S Control Card

 

NXC-IRS4 Send_Commands (Cont.)

 

 

Command

Description

 

 

CH

Send IR pulses for the selected a channel. All channels below 100 are transmitted as two digits. If the

 

IR code for ENTER (function #21) is loaded, an Enter will follow the number. If the channel is greater

 

than or equal to (>=) 100, then IR function 127 or 20 (whichever exists) is generated for the one

 

hundred digit. Uses 'CTON' and 'CTOF' times for pulse times.

 

Syntax:

 

SEND_COMMAND <DEV>,"'CH',<Number>"

 

Variable:

 

channel number = 0 - 199.

 

Example:

 

SEND_COMMAND IR_1,"'CH',18"

 

The NXC-IRS4 performs the following:

 

• Transmits IR signals for 1 (IR code 11). The transmit time is set with the CTON command.

 

• Waits until the time set with the CTOF command elapses.

 

• Transmits IR signals for 8 (IR code 18).

 

• Waits for the time set with the CTOF command elapses. If the IR code for Enter (IR code 21) is

 

programmed, the IRS4 performs the following steps.

 

• Transmits IR signals for Enter (IR code 21).

 

Waits for the time set with the CTOF command elapses.

 

 

CP

Halt and Clear all active or buffered IR commands, and then send a single IR pulse. You can set the

 

Pulse and Wait times with the 'CTON' and 'CTOF' commands.

 

Syntax:

 

SEND_COMMAND <DEV>,"'CP',<code>"

 

Variable:

 

code = IR port's channel value 0 - 252 (253 - 255 reserved).

 

Example:

 

SEND_COMMAND IR_1,"'CP',2"

 

Clears the active/buffered commands and pulses IR_1 port's channel 2.

 

 

CTOF

Set the duration of the Off time (no signal) between IR pulses for channel and IR function

 

transmissions. Off time settings are stored in non-volatile memory. This command sets the delay time

 

between pulses generated by the 'CH' or 'XCH' send commands in tenths of seconds.

 

Syntax:

 

SEND_COMMAND <DEV>,"'CTOF',<time>"

 

Variable:

 

time = 0 - 255. Given in 1/10ths of a second. Default is 5 (0.5 seconds).

 

Example:

 

SEND_COMMAND IR_1,"'CTOF',10"

 

Sets the Off time between each IR pulse to 1 second.

 

 

CTON

Set the total time of IR pulses transmitted and is stored in non-volatile memory. This command sets

 

the pulse length for each pulse generated by the 'CH' or 'XCH' send commands in tenths of seconds.

 

Syntax:

 

SEND_COMMAND <DEV>,"'CTON',<time>"

 

Variable:

 

time = 0 - 255. Given in 1/10ths of a second. Default is 5 (0.5 seconds).

 

Example:

 

SEND_COMMAND IR_1,"'CTON',20"

 

Sets the IR pulse duration to 2 seconds.

 

 