NXF CardFrame and NetModules
NXF CardFrame and NetModules
Overview
NetLinx Control Cards can be installed in the NetLinx® (NXF) CardFrame, the
• | Dual COM Port Control Card | |
• | Input/Output Control Card | |
• | ||
• | Relay Control Card | |
• | Analog Voltage Control Card | |
• | Volume Control Card |
NXF CardFrame
FIG. 1 shows the front and rear panel components of the NXF CardFrame.
Control Card slots
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Master/Hub Card slot |
|
|
|
|
|
|
|
|
|
|
|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
|
|
|
| Cardframe number DIP Switch |
|
|
|
| |
| front | |||
| ||||
|
|
|
|
| 12 | 11 | 10 | 9 |
| 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 12VDC |
| NXF |
1 |
|
| 1 |
| 1 |
|
| 1 |
| 1 |
| 1 |
| CARDFRAME NUMBER | CARDFRAME | |
2 | 2 |
| 2 | 2 | 2 | 2 |
| 2 | 2 | 2 | 2 | 2 | 2 |
| ON |
|
3 | 3 |
| 3 | 3 | 3 | 3 |
| 3 | 3 | 3 | 3 | 3 | 3 |
|
| |
4 | 4 |
| 4 | 4 | 4 | 4 |
| 4 | 4 | 4 | 4 | 4 | 4 |
|
|
|
5 | 5 |
| 5 | 5 | 5 | 5 |
| 5 | 5 | 5 | 5 | 5 | 5 | CARDFRAME |
|
|
6 | 6 |
| 6 | 6 | 6 | 6 |
| 6 | 6 | 6 | 6 | 6 | 6 | PWR |
|
|
7 | 7 |
| 7 | 7 | 7 | 7 |
| 7 | 7 | 7 | 7 | 7 | 7 |
|
|
|
8 | 8 |
| 8 | 8 | 8 | 8 |
| 8 | 8 | 8 | 8 | 8 | 8 |
|
|
|
9 | 9 |
| 9 | 9 | 9 | 9 |
| 9 | 9 | 9 | 9 | 9 | 9 |
|
|
|
10 | 10 |
| 10 | 10 | 10 | 10 |
| 10 | 10 | 10 | 10 | 10 | 10 |
| Master/Hub Card slot |
|
13 | 13 |
| 13 | 13 | 13 | 13 |
| 13 | 13 | 13 | 13 | 13 | 13 |
|
| |
11 | 11 |
| 11 | 11 | 11 | 11 |
| 11 | 11 | 11 | 11 | 11 | 11 |
|
|
|
12 | 12 |
| 12 | 12 | 12 | 12 |
| 12 | 12 | 12 | 12 | 12 | 12 |
|
|
|
14 | 14 |
| 14 | 14 | 14 | 14 |
| 14 | 14 | 14 | 14 | 14 | 14 |
|
|
|
15 | 15 |
| 15 | 15 | 15 | 15 |
| 15 | 15 | 15 | 15 | 15 | 15 |
|
|
|
16 | 16 |
| 16 | 16 | 16 | 16 |
| 16 | 16 | 16 | 16 | 16 | 16 |
|
|
|
17 | 17 |
| 17 | 17 | 17 | 17 |
| 17 | 17 | 17 | 17 | 17 | 17 |
|
|
|
18 | 18 |
| 18 | 18 | 18 | 18 |
| 18 | 18 | 18 | 18 | 18 | 18 |
|
|
|
19 | 19 |
| 19 | 19 | 19 | 19 |
| 19 | 19 | 19 | 19 | 19 | 19 |
|
|
|
20 |
|
| 20 |
| 20 |
|
| 20 |
| 20 |
| 20 |
|
|
|
|
12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
| rear |
| Control Card slots |
|
|
|
|
FIG. 1 NXF CardFrame
NXF Cardframe Specifications
NXF Cardframe Specifications
Power Requirement | 12 VDC; varies with installed Control Cards. |
|
|
Dimensions (HWD) | 3.5" x 17.0" x 9.6" (8.89 cm x 43.18 cm x 24.38 cm) |
|
|
Weight | 9.1 lbs (4.1 kg) |
|
|
Front Panel Components: |
|
Master/Hub Card slot | Houses the Master or Hub Card. Refer to the NetLinx Master Cards and Modules or |
| NetLinx Hub Cards and Modules instruction manuals for detailed information. |
Control Card slots |
|
12 card slots for the NetLinx Control Cards that control devices connected to the | |
| CardFrame. |
|
|
NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide | 1 |
|
|