NXF CardFrame and NetModules

NXF CardFrame and NetModules

Overview

NetLinx Control Cards can be installed in the NetLinx® (NXF) CardFrame, the NI-4000, or in modules for stand-alone operation. The NXF CardFrame accommodates a NetLinx Master (or Hub) card, up to twelve NetLinx Control cards, and provides a back plane to distribute power and data to/from the cards. The NXF CardFrame provides terminals on the rear panel for connection to the control cards and a system power supply. A DIP switch on the rear panel sets the CardFrame's base device number. The NetLinx Control Cards covered in this document are:

NXC-COM2

Dual COM Port Control Card

NXC-I/O10

Input/Output Control Card

NXC-IRS4

4-Port IR/S Control Card

NXC-REL10

Relay Control Card

NXC-VAI4

Analog Voltage Control Card

NXC-VOL4

Volume Control Card

NXF CardFrame

FIG. 1 shows the front and rear panel components of the NXF CardFrame.

Control Card slots 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Master/Hub Card slot

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

 

 

 

 

Cardframe number DIP Switch

 

 

 

 

 

front

 

2-pin 12V power connector

 

 

 

 

 

12

11

10

9

 

8

7

6

5

4

3

2

1

12VDC

 

NXF

1

 

 

1

 

1

 

 

1

 

1

 

1

 

CARDFRAME NUMBER

CARDFRAME

2

2

 

2

2

2

2

 

2

2

2

2

2

2

 

ON

 

3

3

 

3

3

3

3

 

3

3

3

3

3

3

 

 

4

4

 

4

4

4

4

 

4

4

4

4

4

4

 

 

 

5

5

 

5

5

5

5

 

5

5

5

5

5

5

CARDFRAME

 

 

6

6

 

6

6

6

6

 

6

6

6

6

6

6

PWR

 

 

7

7

 

7

7

7

7

 

7

7

7

7

7

7

 

 

 

8

8

 

8

8

8

8

 

8

8

8

8

8

8

 

 

 

9

9

 

9

9

9

9

 

9

9

9

9

9

9

 

 

 

10

10

 

10

10

10

10

 

10

10

10

10

10

10

 

Master/Hub Card slot

 

13

13

 

13

13

13

13

 

13

13

13

13

13

13

 

 

11

11

 

11

11

11

11

 

11

11

11

11

11

11

 

 

 

12

12

 

12

12

12

12

 

12

12

12

12

12

12

 

 

 

14

14

 

14

14

14

14

 

14

14

14

14

14

14

 

 

 

15

15

 

15

15

15

15

 

15

15

15

15

15

15

 

 

 

16

16

 

16

16

16

16

 

16

16

16

16

16

16

 

 

 

17

17

 

17

17

17

17

 

17

17

17

17

17

17

 

 

 

18

18

 

18

18

18

18

 

18

18

18

18

18

18

 

 

 

19

19

 

19

19

19

19

 

19

19

19

19

19

19

 

 

 

20

 

 

20

 

20

 

 

20

 

20

 

20

 

 

 

 

12

11

10

9

8

7

6

5

4

3

2

1

 

 

rear

 

Control Card slots 1-12

 

 

 

 

FIG. 1 NXF CardFrame

NXF Cardframe Specifications

NXF Cardframe Specifications

Power Requirement

12 VDC; varies with installed Control Cards.

 

 

Dimensions (HWD)

3.5" x 17.0" x 9.6" (8.89 cm x 43.18 cm x 24.38 cm)

 

 

Weight

9.1 lbs (4.1 kg)

 

 

Front Panel Components:

 

Master/Hub Card slot

Houses the Master or Hub Card. Refer to the NetLinx Master Cards and Modules or

 

NetLinx Hub Cards and Modules instruction manuals for detailed information.

Control Card slots

 

12 card slots for the NetLinx Control Cards that control devices connected to the

 

CardFrame.

 

 

NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide

1

 

 

Page 7
Image 7
AMX nxc manual NXF CardFrame and NetModules, Overview, NXF Cardframe Specifications