AMX nxc manual Level Value

Models: nxc

1 46
Download 46 pages 61.34 Kb
Page 38
Image 38

NXC-VAI4 Analog Voltage Control Card

NXC-VAI4 Send_Commands (Cont.)

Command

Description

 

 

PN

Sets the value of either the minimum output voltage allowed for an output, or the minimum position

 

voltage expected for an input. Voltage settings are rounded to the nearest D/A or A/D code. Voltage

 

settings for Outputs are absolute levels and are unaffected by any software scaling functions. Negative

 

voltages are not valid for Input 3.

 

Syntax:

 

SEND_COMMAND <DEV>,'P<I/O>N<LEVEL VALUE>'

 

Variables:

 

I/O: Any input or output ('1','2','3','4','5','6','7','8')

 

LEVEL VALUE: -12.000V to +12.000V

 

Examples:

 

SEND_COMMAND <DEV>,'P1N5.023V'

 

Sets the minimum output level for Output 1 to 5.023V.

 

SEND_COMMAND <DEV>,'P1N-5.023V'

 

Sets the minimum output level for Output 1 to -5.023V.

 

SEND_COMMAND <DEV>,'P7N5.023V'

 

Sets the minimum of the expected input range for Input 7 to 5.023V.

 

 

PR

Sets the CURRENT OUTPUT <x> RAMP UP TIME and/or CURRENT OUTPUT <x> RAMP DOWN

 

TIME of the specified Output where TIME is the time to ramp the full range. It can be set to ramp both

 

down to up and up to down or just down to up or just up to down.

 

Syntax:

 

SEND_COMMAND <DEV>,'P<OUTPUT>R<TIME>[UD]'

 

Variables:

 

OUTPUT: Any Output '1', '2', '3', or '4'

 

TIME: 0 - 255 in 0.1 second increments

 

U/D: Ramp Up (U) or Down (D)

 

Examples:

 

SEND_COMMAND <DEV>,'P1R25'

 

Sets CURRENT OUTPUT 1 RAMP UP TIME" and "CURRENT OUTPUT 1 RAMP DOWN TIME" to

 

2.5 seconds each for full range travel.

 

SEND_COMMAND <DEV>,'P2R75U'

 

Sets CURRENT OUTPUT 2 RAMP UP TIME to 7.5 seconds for full range travel, CURRENT OUTPUT

 

2 RAMP DOWN TIME remains unchanged.

 

SEND_COMMAND <DEV>,'P2R50D'

 

Sets "CURRENT OUTPUT 2 RAMP DOWN TIME" to 5 seconds for full range travel; "CURRENT

 

OUTPUT 2 RAMP UP TIME" remains unchanged.

 

 

PU

Sets the level to which this Output is set immediately after power-up and before any Output is

 

commanded.

 

Syntax:

 

SEND_COMMAND <DEV>,'P<OUTPUT>U<LEVEL VALUE>'

 

Variables:

 

OUTPUT: Any Output ('1', '2', '3', or '4')

 

LEVEL VALUE: 0-255

 

Example:

 

SEND_COMMAND <DEV>,'P1U127'

 

Sets the power up output level for Output 1 to 127.

 

 

32

NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide

Page 38
Image 38
AMX nxc manual Level Value