![](/images/new-backgrounds/1306409/30640949x1.webp)
NXC-IRS4 Send_Commands (Cont.)
PTOF | Set the time duration between power pulses |
| This time increment is stored in permanent memory. This command also sets the delay between |
| pulses generated by the 'PON' or 'POF' send commands in tenths of seconds. It also sets the delay |
| required after a power ON command before a new IR function can be generated. This gives the |
| device time to power up and get ready for future IR commands. It also sets the delay required after a |
| power ON command before a new IR function can be generated. This gives the device time to power |
| up and get ready for future IR commands. |
| Syntax: |
| SEND_COMMAND <DEV>,"'PTOF',<time>" |
| Variable: |
| time = 0 - 255. Given in 1/10ths of a second. Default is 15 (1.5 seconds). |
| Example: |
| SEND_COMMAND IR_1,"'PTOF',15" |
| Sets the time between power pulses to 1.5 seconds for the IR_1 device. |
|
|
PTON | Set the time duration between power pulses |
| This time increment is stored in permanent memory. This command also sets the pulse length for |
| each pulse generated by the 'PON' or 'POF' send commands in tenths of seconds. |
| Syntax: |
| SEND_COMMAND <DEV>,"'PTON',<time>" |
| Variable: |
| time = 0 - 255. Given in 1/10ths of a second. Default is 5 (0.5 seconds). |
| Example: |
| SEND_COMMAND IR_1,"'PTON',15" |
| Sets the duration of the power pulse to 1.5 seconds for the IR_1 device. |
|
|
SET INPUT LINK | Sets an IR device to link to an input channel for use with 'PON' and 'POF' commands. The input |
| channel is used for power sensing (via a PCS). A channel of zero disables the link. |
| Syntax: |
| SEND_COMMAND <DEV>,"'SET INPUT LINK <channel>'" |
| Variable: |
| channel = 1 - 4. Setting the channel to 0 disables the link. |
| Example: |
| SEND_COMMAND IR_1,"'SET INPUT LINK 1'" |
| Sets the IR_1 port link to I/O channel 1. The IR port uses the specified input as power status for |
| processing PON and POF commands. |
|
|
SET IO LINK | Link an IR or Serial port to a selected I/O channel for use with the 'DE', 'POD', 'PON', and 'POF' |
| commands. The I/O status is automatically reported on channel 255 on the IR port. The I/O channel |
| is used for power sensing (via a PCS or VSS). A channel of zero disables the I/O link. |
| Syntax: |
| SEND_COMMAND <DEV>,"'SET IO LINK <I/O number>'" |
| Variable: |
| I/O number = 1 - 4. Setting the I/O channel to 0 disables the I/O link. |
| Example: |
| SEND_COMMAND IR_1,"'SET INPUT LINK 1'" |
| Sets the IR_1 port link to I/O channel 1. The IR port uses the specified input as power status for |
| processing PON and POF commands. |
| Note: This command is included for older programs only. The Input port is not an I/O. No output |
| functions are available.’SET IO LINK’ applies the same configuration as the ’SET INPUT LINK’ |
| command. |
|
|
NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide | 19 |
|
|