NXC-VAI4 Analog Voltage Control Card
27
NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide
NXC-VAI4 Channel Assignments (Cont.)
Channel State Function
4 ON While channel 4 is ON, the voltage on Output 4 will ramp up at the "CURRENT OUTPUT 4
RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF Stops voltage ramping on Output 4 at current value.
5 ON While channel 5 is ON, the voltage on Output 1 will ramp down at the "CURRENT OUTPUT 1
RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is reached.
OFF Stops voltage ramping on Output 1 at current value.
6 ON While channel 6 is ON, the voltage on Output 2 will ramp down at the "CURRENT OUTPUT 2
RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is reached.
OFF Stops voltage ramping on Output 2 at current value.
7 ON While channel 7 is ON, the voltage on Output 3 will ramp down at the "CURRENT OUTPUT 3
RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is reached.
OFF Stops voltage ramping on Output 3 at current value.
8 ON While channel 8 is ON, the voltage on Output 4 will ramp down at the "CURRENT OUTPUT 4
RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is reached.
OFF Stops voltage ramping on Output 4 at current value.
9 ON Reserved [do not use]
OFF Reserved [do not use]
10 ON While channel 10 is ON, the voltage on Output 1 is set to 100%
OFF Sets Output 1 voltage to 50%.
11 ON While channel 11 is ON, the voltage on Output 2 is set to 100%
OFF Sets Output 2 voltage to 50%.
12 ON While channel 12 is ON, the voltage on Output 3 is set to 100%
OFF Sets Output 3 voltage to 50%.
13 ON While channel 13 is ON, the voltage on Output 4 is set to 100%
OFF Sets Output 4 voltage to 50%.
14 ON While channel 14 is ON, the voltage on Output 1 is set to 0%
OFF Sets Output 1 voltage to 50%.
15 ON While channel 15 is ON, the voltage on Output 2 is set to 0%
OFF Sets Output 2 voltage to 50%.
16 ON While channel 16 is ON, the voltage on Output 3 is set to 0%
OFF Sets Output 3 voltage to 50%.
17 ON While channel 17 is ON, the voltage on Output 4 is set to 0%
OFF Sets Output 4 voltage to 50%.
18 ON While channel 18 is ON, the voltage on Output 1 is set to 75%
OFF Sets Output 1 voltage to 50%.
19 ON While channel 19 is ON, the voltage on Output 2 is set to 75%
OFF Sets Output 2 voltage to 50%.
20 ON While channel 20 is ON, the voltage on Output 3 is set to 75%
OFF Sets Output 3 voltage to 50%.
21 ON While channel 21 is ON, the voltage on Output 4 is set to 75%
OFF Sets Output 4 voltage to 50%.
22 ON While channel 22 is ON, the voltage on Output 1 is set to 25%
OFF Sets Output 1 voltage to 50%.