NXC-VAI4 Analog Voltage Control Card

 

NXC-VAI4 Channel Assignments (Cont.)

 

 

 

Channel

State

Function

 

 

 

4

ON

While channel 4 is ON, the voltage on Output 4 will ramp up at the "CURRENT OUTPUT 4

 

 

RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.

 

 

 

 

OFF

Stops voltage ramping on Output 4 at current value.

 

 

 

5

ON

While channel 5 is ON, the voltage on Output 1 will ramp down at the "CURRENT OUTPUT 1

 

 

RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is reached.

 

 

 

 

OFF

Stops voltage ramping on Output 1 at current value.

 

 

 

6

ON

While channel 6 is ON, the voltage on Output 2 will ramp down at the "CURRENT OUTPUT 2

 

 

RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is reached.

 

 

 

 

OFF

Stops voltage ramping on Output 2 at current value.

 

 

 

7

ON

While channel 7 is ON, the voltage on Output 3 will ramp down at the "CURRENT OUTPUT 3

 

 

RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is reached.

 

 

 

 

OFF

Stops voltage ramping on Output 3 at current value.

 

 

 

8

ON

While channel 8 is ON, the voltage on Output 4 will ramp down at the "CURRENT OUTPUT 4

 

 

RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is reached.

 

 

 

 

OFF

Stops voltage ramping on Output 4 at current value.

 

 

 

9

ON

Reserved [do not use]

 

 

 

 

OFF

Reserved [do not use]

 

 

 

10

ON

While channel 10 is ON, the voltage on Output 1 is set to 100%

 

 

 

 

OFF

Sets Output 1 voltage to 50%.

 

 

 

11

ON

While channel 11 is ON, the voltage on Output 2 is set to 100%

 

 

 

 

OFF

Sets Output 2 voltage to 50%.

 

 

 

12

ON

While channel 12 is ON, the voltage on Output 3 is set to 100%

 

 

 

 

OFF

Sets Output 3 voltage to 50%.

 

 

 

13

ON

While channel 13 is ON, the voltage on Output 4 is set to 100%

 

 

 

 

OFF

Sets Output 4 voltage to 50%.

 

 

 

14

ON

While channel 14 is ON, the voltage on Output 1 is set to 0%

 

 

 

 

OFF

Sets Output 1 voltage to 50%.

 

 

 

15

ON

While channel 15 is ON, the voltage on Output 2 is set to 0%

 

 

 

 

OFF

Sets Output 2 voltage to 50%.

 

 

 

16

ON

While channel 16 is ON, the voltage on Output 3 is set to 0%

 

 

 

 

OFF

Sets Output 3 voltage to 50%.

 

 

 

17

ON

While channel 17 is ON, the voltage on Output 4 is set to 0%

 

 

 

 

OFF

Sets Output 4 voltage to 50%.

 

 

 

18

ON

While channel 18 is ON, the voltage on Output 1 is set to 75%

 

 

 

 

OFF

Sets Output 1 voltage to 50%.

 

 

 

19

ON

While channel 19 is ON, the voltage on Output 2 is set to 75%

 

 

 

 

OFF

Sets Output 2 voltage to 50%.

 

 

 

20

ON

While channel 20 is ON, the voltage on Output 3 is set to 75%

 

 

 

 

OFF

Sets Output 3 voltage to 50%.

 

 

 

21

ON

While channel 21 is ON, the voltage on Output 4 is set to 75%

 

 

 

 

OFF

Sets Output 4 voltage to 50%.

 

 

 

22

ON

While channel 22 is ON, the voltage on Output 1 is set to 25%

 

 

 

 

OFF

Sets Output 1 voltage to 50%.

 

 

 

NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide

27

 

 

Page 33
Image 33
AMX nxc manual Stops voltage ramping on Output 4 at current value