NXC-VAI4 Analog Voltage Control Card
25
NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide
NXC-VAI4 Analog Voltage Control Card

The NXC-VAI4 Analog Voltage Control Card (FG2025) provides four independent analog-to-digital inputs and four

independent digital-to-analog outputs, which are controllable over the ICSP network.

Each port can be configured for a variety of DC input and output signals.

The NXC-VAI4 incorporates the functionality of the AXC-VAI2 and AXC-VRG AXlink cards. FIG.7 shows the VAI4

card:

Specifications
FIG. 7 NXC-VAI4 Analog Voltage Control card

NXC-VAI4 Specifications

Power Requirements 330 mA @ 12 VDC
Inputs Four high-impedance analog DC inputs.
Outputs Four analog DC outputs (user-configurable).
D/A, A/D conversion A/D and D/A converters for analog sampling and control. 8 or 10-bit; user-selectable via
the ADMODE SEND_COMMAND (see theProgramming Informationsection on
page29 for details)
Available input voltages 0 V to +12 V
Available output voltages:
-12 V to +12 V The output voltage may be software-configured for any min. and max. levels between -
12 and +12 VDC.
Maximum output current = 60 mA per output.
Over-voltage protection to +28 VDC.
External reference A user supplied external reference voltage can be used to set the maximum voltage
range for the D/A outputs. The full analog output range is scaled to fit the maximum
range set by the external reference.
Output voltage may be set to any level between 0-12 VDC, referenced to the external
reference voltage input and NXC-VAI4 power supply GND.
External reference input:
(EREF - one for each output) Maximum external reference input voltage = +12 VDC.
Over-voltage protection to +28 VDC.
Internal reference output:
(IREF) +5 V reference output, maximum current = 60 mA.
This output is intended to drive a ground-referenced load.