Image 14

ADSP-21020

Interrupts

 

 

 

 

K/B/T Grade

K/B/T Grade

B/T Grade

K Grade

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 MHz

25 MHz

30 MHz

33.3 MHz

Frequency Dependency*

 

Parameter

 

Min Max

Min Max

Min Max

Min Max

Min

Max

Unit

 

 

 

 

 

 

 

 

 

 

Timing Requirement:

 

 

 

 

 

 

 

tSIR IRQ3-0

Setup before CLKIN High

38

31

25

23

38 + 3DT/4

 

ns

tHIR

IRQ

3-0

Hold after CLKIN High

0

0

0

0

 

ns

 

tIPW

IRQ

3-0

Pulse Width

55

45

38

35

tCK + 5

 

ns

NOTE

*DT = tCK – 50 ns

Meeting setup and hold guarantees interrupts will be latched in that cycle. Meeting the pulse width is not necessary if the setup and hold is met. Likewise, meeting the setup and hold is not necessary if the pulse width is met. See the Hardware Configuration chapter of the ADSP-21020 User’s Manual for interrupt servicing informa- tion.

CLKIN

 

 

 

 

t

SIR

tHIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IRQ3-0

 

 

 

 

 

 

 

 

 

 

 

 

tIPW

 

 

 

 

 

 

 

Figure 5. Interrupts

 

 

 

 

Timer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K/B/T Grade

K/B/T Grade

 

B/T Grade

K Grade

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 MHz

25 MHz

 

30 MHz

33.3 MHz

Frequency Dependency*

 

Parameter

 

Min Max

Min Max

 

Min Max

Min Max

Min

Max

Unit

 

 

 

 

 

 

 

 

 

 

Switching Characteristic:

 

 

 

 

 

 

 

 

 

tDTEX CLKIN High to TIMEXP

 

24

24

 

24

24

 

 

ns

NOTE

 

 

 

 

 

 

 

 

 

*DT = tCK – 50 ns

 

 

 

 

 

 

 

 

 

 

CLKIN

 

 

 

 

 

 

 

 

 

t DTEX

 

 

 

tDTEX

 

 

 

TIMEXP

Figure 6. TIMEXP