Argosy Research H-125 Series SET 12000 MIN, 800 MIN, 6000 MIN, Min, Fill, Auto, 64.0 x1K

Models: H-125 Series

1 40
Download 40 pages 39.84 Kb
Page 10
Image 10
Step 4S

SOFTENING TIME

Step 4S

SET 120:00MIN

 

 

 

BACKWASH TIME

Step 5S

SET

8:00MIN

 

 

 

DRAW TIME

Step 6S

SET

60:00MIN

 

 

 

BACKWASH TIME

Step 7S

SET

8:00 MIN

 

 

 

RINSE TIME

Step 8S

SET

4:00 MIN

 

 

 

GRAIN OF CAPACITY

Step 9S

SET

64.0 x1K

 

 

 

NORMAL

Step 10S

SET

FILL

 

 

 

RESERVE CALCULATOR

Step 11S

SET

AUTO

 

 

 

Figure 12a

10

STEP 4 S – Select the time for the second cycle (which in this example is SOFTENING) using or button. Press NEXT to go to Step 5S. Press REGEN to return to the previous step.

STEP 5 S – Select the time for the third cycle (which in this example is BACKWASH) using the or button. Press NEXT to go to Step 6S. Press REGEN to return to the previous step.

STEP 6 S – Select the time for the fourth cycle (which in this example is dn BRINE) using the or button. Press NEXT to go to Step 7S. Press REGEN to return to the previous step.

STEP 7 S – Select the time for the fifth cycle (which in this example is BACKWASH) using the or button. Press NEXT to go to Step 8S. Press REGEN to return to the previous step.

STEP 8 S – Select the time for the sixth cycle (which in this example is RINSE) using the

or button. Press NEXT to go to Step 9S. Press REGEN to return to the previous step.

STEP 9 S - Set Grain Capacity using the or button. The ion exchange capacity is in grains of hardness as calcium carbonate for the system based on the pounds of salt that will be used. The allowable grains capacity range varies from 5,000 to 500,000 grains. The increment increase is 500 for the range from 5000 to 50,000; 1000 for the range of 50,000 to 200,000; and 2000 for the range of 200,000 to 500,000. Grains capacity is affected by the fill time. The grains capacity for the selected lbs. salting should be confirmed by testing. The capacity and hardness levels entered are used to automatically calculate reserve capacity when gallon capacity is set to AUTO. Factory setting is the capacity of the softener at medium salting. See Page 33. Press NEXT to go to Step 10S. Press REGEN to return to previous step.

STEP 10 S – Select between proportional or normal brining. Use or buttons to select. Proportional brining is only available if configured as prefill/upflow softener or screen will not appear. Proportional brining will divide the actual gallons used by calculated volumetric capacity then multiply fill volume by this percentage. This option requires a func- tioning meter. Factory Setting = Normal brining. Press NEXT to go to Step 11S. Press REGEN to return to previous step.

Step 11 S – Set Gallons Capacity using or button. If value is set to:

“AUTO” gallon capacity will be automatically calculated and reserve capacity will be auto- matically estimated;

“oFF” regeneration will be based solely on the day override set (see Installer Display/Set- tings Step 3, page 8 / proportional brining will not fuction if OFF selected); or

as a number of gallons (allowable range 20 to 250,000) regeneration will be based on the value specified.

Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000 and 500 for the range of 10,000 to 50,000 and 2000 for range of 50,000 to 250,000.

If “oFF” or a number is used, hardness cannot be set in Installer Displays/Settings Step 2, page 8. See page 34 for more detail. Factory Setting is AUTO. Press NEXT to go to Step 12 S. Press REGEN to return to previous step.

Page 10
Image 10
Argosy Research H-125 Series owner manual SET 12000 MIN, 800 MIN, 6000 MIN, Min, Fill, Auto, 64.0 x1K