Argosy Research H-125 Series owner manual Programming options, GENERAL specifications

Models: H-125 Series

1 40
Download 40 pages 39.84 Kb
Page 34
Image 34
Programming options

Programming options

Reserve

Regeneration

Days

Results

Gallons

Type

Override

(Reserve capacity estimate based on history of water usage)

AUTO

DELAY

oFF

Reserve capacity automatically estimated.

Regeneration occurs when gallons capacity falls below the reserve capacity at the next

 

 

 

Regen Set Time.

AUTO

DELAY

1 to 28

Reserve capacity automatically estimated.

Regeneration occurs at the next Regen Set Time when gallons capacity falls below the

 

 

 

reserve capacity or the specified number of days between regenerations is reached.

20 to

DELAY

oFF

Reserve capacity not automatically estimated.

250,000

Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0.

 

 

oFF

DELAY

1 to 28

Reserve capacity not automatically estimated.

Regeneration occurs at the next Regen Set Time when the specified number of days

 

 

 

between regenerations is reached.

20 to

DELAY

1 to 28

Reserve capacity not automatically estimated.

Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the

250,000

 

 

specified number of days between regenerations is reached.

 

 

 

 

 

 

Reserve capacity not automatically estimated.

AUTO

IMMEDIATE

oFF

Regeneration occurs immediately when gallons capacity reaches 0.

Time of regeneration will not be allowed to be set because of regeneration will always

 

 

 

 

 

 

occur when gallons capacity reaches 0.

 

 

 

 

20 to

 

 

Reserve capacity not automatically estimated.

DELAY + IMMEDIATE

oFF

Regeneration occurs immediately when gallons capacity reaches 0.

250,000

 

 

Time of regeneration will not be allowed to be set because regeneration will always

 

 

 

occur on 0.

 

 

 

Reserve capacity automatically estimated.

AUTO

DELAY + IMMEDIATE

oFF

Regeneration occurs when gallons capacity falls below the reserve

 

 

 

capacity at the next Regen Set Time or regeneration occurs immediately after

 

 

 

10 minutes of no water usage when gallon capacity reaches 0.

 

 

1 to 28

Reserve capacity automatically estimated.

AUTO*

DELAY + IMMEDIATE

Regeneration occurs at the next Regen Set Time when gallons capacity

*14

falls below the reserve capacity or the specified number of days between regenerations

 

 

 

is reached or regeneration occurs immediately after 10

 

 

 

minutes of no water usage when gallon capacity reaches 0.

 

 

 

Reserve capacity not automatically estimated.

20 to

DELAY + IMMEDIATE

1 to 28

Regeneration occurs at the next Regen Set Time when specified number of days be-

250,000

 

 

tween regenerations is reached or regeneration occurs immediately after 10 minutes

 

 

 

of no water usage when gallon capacity reaches 0.

 

 

 

 

*Factory settings in bold

To "lockout" access to modification settings, diagnostic and valve history displays except hardness, day override and time,

press *Factory settings in bold next,GENERAL specifications and clock in sequence to "unlock" pressManual backgroundManual background next,Manual background and clock in sequence.

OPERATING PRESSURES

GENERAL specifications

 

 

25 psi-125 psi

Minimum/Maximum

OPERATING TEMPERATURES

 

40º - 110º F

Minimum/Maximum

METER

 

±5%

Accuracy

Flow Rate Range

0.25 - 34 GPM

Gallon Range

20 - 50,000

DIMENSIONS

 

3/4” or 1” NPT

Drain Line

Brine Line

3/8” Poly Tube

Electrical Current Draw and Voltage

0.5A 110v

Compatible with the following regenerants or chemicals: Sodium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide, hydroxide, hydrochloric acid, chlorine and chloramines.

34

Page 34
Image 34
Argosy Research H-125 Series owner manual Programming options, GENERAL specifications, Factory settings in bold