relay troubleshooting

PROBLEM

 

CAUSE

20.

Relay does not energize

 

 

A.

Relay driver programmed on "Time"

A.

Programmed incorrectly

 

 

B. Faulty wire connections between

 

 

 

PC board and relay

 

 

C.

Defective PC Board

 

 

D. Defective relay, See figure below

B.Relay driver programmed on "Gallons" A. Programmed incorrectly

B.Defective PC Board

C.Defective relay, See figure below

D.Faulty meter connection

E.Faulty wire connections between PC board and relay

CORRECTION

A.Reprogram, see page 11

B.Check and repair wire connections

C.Replace PC Board

D.Replace Relay

A.Reprogram, see page 11

B.Replace PC Board

C.Replace Relay

D.Repair or replace meter assembly

E.Check and repair wire connections

21

Page 21
Image 21
Argosy Research H-125 Series owner manual Relay troubleshooting, Problem Cause