Argosy Research H-125 Series H125 SPECIFICATIONS, Factory Regeneration, Settings, 28,000, 42,000

Models: H-125 Series

1 40
Download 40 pages 39.84 Kb
Page 33
Image 33
H125 SPECIFICATIONS

H125 SPECIFICATIONS

 

 

H125

H125

H125

H125

H125

H125

H125

Model #

 

32-10

48

64

96

128

160

192

Factory Regeneration

 

 

 

 

 

 

 

Settings

 

 

 

 

 

 

 

 

Backwash

Minutes

8

8

8

8

8

8

8

 

Gallons

18

18

34

34

42

60

60

Brine/Rinse

Minutes

60

60

68

68

68

68

68

 

Gallons

19.2

22.2

43.5

47.7

71.1

89.1

113

Backwash

Minutes

8

8

8

8

8

8

8

 

Gallons

18

18

34

34

42

60

60

Fast Rinse

Minutes

4

4

4

4

4

4

4

 

Gallons

9

9

17

17

21

30

30

Fill

Minutes

6:32

9:53

13:14

19:56

26:38

33:20

40:02

 

Gallons

3.2

4.7

6.5

9.8

13.2

16.6

20

Total Regeneration Gallons*

66

71

134

142

190

256

283

* Calculations are based on factory medium salt setting @ 50 psi

 

 

 

 

 

 

 

 

 

 

 

 

Refill LBS of salt

Lbs.

Lbs.

Lbs.

Lbs.

Lbs.

Lbs.

Lbs.

Low Salt

 

6

9

12

18

24

30

36

Medium Salt

 

10

15

20

30

40

50

60

High Salt

 

15

22.5

30

45

60

75

90

 

 

 

 

 

 

 

 

 

Capacity

 

Grains

Grains

Grains

Grains

Grains

Grains

Grains

Low Salt

 

19,000

28,500

38,000

57,000

76,000

95,000

114,000

Medium Salt

 

28,000

42,000

56,000

84,000

112,000

140,000

168,000

High Salt

 

32,000

48,000

64,000

96,000

128,000

160,000

192,000

 

 

 

 

 

 

 

 

Service Flow Rates

GPM

GPM

GPM

GPM

GPM

GPM

GPM

Continuous @ 15 psi

22

19

25

24

25

27

26

Peak @ 25 psi

31

28

34

33

34

35

34

 

 

 

 

 

 

 

 

Flint Under bed (lbs.)

14

14

40

40

45

50

75

High Capacity Resin (cu.ft.)

1

1.5

2

3

4

5

6

Resin Tank Size

10x44

10x54

13x54

14x65

16x65

18x65

18x65

Recommended Brine Tank

18x40

18x40

18x40

18x40

24x41

24x50

24x50

Brine Line Size

3/8”

3/8"

3/8"

3/8"

3/8"

1/2"

1/2"

DLFC (gpm)

 

2.2

2.2

4.2

4.2

5.3

7.5

7.5

BLFC (gpm)

 

0.5

0.5

0.5

0.5

0.5

0.5

0.5

Injector Size

 

D-Red

E-White

G-Yellow

H-Green

I-Orange

J- Lt. Blue

K- Lt. Green

Injector Draw Rate @ 50 psi

0.22

0.27

0.46

0.46

0.6

0.7

0.7

Injector Slow Rinse @ 50 psi

0.32

0.37

0.64

0.71

1.1

1.4

1.8

33

Page 33
Image 33
Argosy Research H-125 Series H125 SPECIFICATIONS, Factory Regeneration, Settings, 28,000, 42,000, 56,000, 84,000, 112,000