water meter and meter plug

ITEM NO.

ORDER NO.

DESCRIPTION

QTY.

1

15-V3151

Nut 1” QC

1

2-4

15-V3003*

Meter Assy.

1

3

15-V3118-01

Turbine Assy.

1

4

15-V3105

O-ring 215

1

5

15-V3003-01

Meter Plug Assy.**

1

*Order number 15-V3003 includes 15-V3118-01 and 15-V3103, which are item numbers 3 & 4.

**Only used if metering is not to be done (time clock units)

The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench. If necessary a pliers can be used to un- screw the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place screwdriver in slots on caps and/or tap with a hammer.

￿

￿

￿

￿

￿

bypass valve

ITEM NO.

ORDER NO.

DESCRIPTION

QTY.

Not Shown

15-V3191-01

Bypass 90º Vert. Assy.

 

1

15-V3151

Nut 1” Quick Connect

2

2

15-V3150

Split Ring

2

3

15-V3105

O-Ring 215

2

Not Shown

15-V3191-01

Bypass Vertical Adpt.Assy (set of 2)

1

The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench. If necessary a pliers can be used to un- screw the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place screwdriver in slots on caps and/or tap with a hammer.

Do not use pipe dope or other sealants on threads. Teflon tape must be used on threads of the 1” NPT connection and on the threads for the drain line connection. Teflon tape is not necessary on the nut connection nor caps because of o-ring seals.

Figure 20

Figure 21

27

Page 27
Image 27
Argosy Research H-125 Series owner manual Water meter and meter plug, Bypass valve