AUDIX Voice Power Initial Implementation

Switch Interface Administration Parameters

Some specific parameters are necessary to tell AUDIX Voice Power how to communicate with the telephone switch. For convenience, these parameters are collected on FORM B in the Planning Guide. A sample is explained below.

FORM B

 

Switch Interface Administration

 

 

Switchhook Flash Duration

I

Wink Disconnect Interval

I

Signaling Type

I

The contents of each field should be:

Switchhook Flash Duration specifies the on-hook duration in milliseconds that the switch recognizes as a transfer request. The range is 300 to 1550 milliseconds. . The default is 600 milliseconds,

Wink Disconnect Interval specifies the on-hook duration in milliseconds that the switch recognizes as a disconnect request. The range is 300 to 800 milliseconds. The default is 300 milliseconds.

Signaling Type specifies whether Touch-Tone (TT) or dial-pulse (DP) signaling is used. The default is TT.

Changing Switch Interface Parameters

The switch interface parameters should not be changed from the values specified above. If for some reason they must be changed, enter the default values shown above. The new values will replace the old values,