Appendix
Administrator Login Failure
If you are unable to perform an Administrator login (because the Username and Password information has become corrupted, or you have forgotten it, for example), there is a procedure you can use to clear the login information.
Note: Performing this procedure also returns all settings to their defaults.
To clear the login information (and return all settings to their defaults), do the following:
1.Power off the KH1508Ai / KH1516Ai and remove its housing.
2.Using a jumper cap, short the jumper on the IP module (the daughter card located at the
J15
3.Power on the switch.
4.Wait a few seconds. When the front panel LEDs flash, power off the switch.
5.Remove the jumper cap from J15.
6.Close the housing and power on the KH1508Ai / KH1516Ai.
After powering on the unit, you can use the default Username and Password (see OSD Overview, page 25), to log in.
183