Atlantis Land A02-RA(Atmos)_ME01 manual enable, errors, etherfiles, Syntax, Description, Example

Models: A02-RA(Atmos)_ME01

1 112
Download 112 pages 14.35 Kb
Page 79
Image 79

device ether ether //edd mtu 1500 192.168.2.1

device flane ether //lec1 mtu 1500 192.168.55.1

#DISABLED

10.9enable

10.9.1 Syntax

enable [<i/f> [mtu <size>] [<IP address>]]

10.9.2 Description

Enables all interfaces, or just a specified interface. Can also be used to set the MTU and IP address on an interface when enabling it (or change them on an interface that is already enabled); see device on page 162 for details on the interfaces.

Configuration saving saves the MTU and IP addresses, but not the disabled/enabled state.

10.9.3 Example

mymachine> ip enable flane 192.168.56.3

 

ip/flane: IP address 192.168.56.3

 

mymachine> ip device

 

 

#

type

dev file

IP address

device ether ether //edd mtu 1500 192.168.2.1 device flane ether //lec1 mtu 1500 192.168.56.3

10.10 errors

10.10.1Syntax

errors

10.10.2Description

Turns on tracing of various unusual events; equivalent to trace errors.

The errors command is hidden, not shown by ip help.

10.10.3Example

mymachine> ip errors

ip: currently tracing errors

10.11 etherfiles

10.11.1Syntax

etherfiles

10.11.2Description

Lists the file names for the underlying devices for all Ethernet-like interfaces.

Page 79
Image 79
Atlantis Land A02-RA(Atmos)_ME01 manual enable, errors, etherfiles, Example, 10.10.1Syntax, 10.10.2Description