Avery 676 user manual Electrical Trouble Shooting, Power Up / Sign On / Communications

Models: 676

1 79
Download 79 pages 40.88 Kb
Page 46
Image 46

Electrical Trouble Shooting

Power Up / Sign On / Communications

Problem

 

Probable Cause

Corrective Action

 

 

 

 

Machine fails to power up

1)

Incorrect power voltage.

1) Confirm that the AC entry is configured for the

with no light present in

 

 

line voltage intended to be applied to the

the AC power switch.

 

 

machine. Failure to do so can damage the

 

 

 

machine's internal power supply. Refer to the

 

 

 

"Fuse Configuration".

 

 

 

 

 

2)

Lack of power to machine.

2) Check that both ends of the power cord are

 

 

 

plugged in securely.

 

 

 

2A) Confirm that the outlet the machine is plugged

 

 

 

into has power.

 

 

 

 

 

3)

Missing or blown fuse(s)

3) Check that the fuse(s) located inside the AC

 

 

 

entry are present and intact. Replace as needed.

 

 

 

Refer to the "Fuse Configuration".

 

 

 

 

Machine fails to power up with light present in the AC power switch.

1)Unconnected cable / connector inside machine.

1)Power off and remove the power cord from the AC entry. Remove the back cover and inspect the cables and connectors to and from the power supply. Refer to the "Electrical System Schematic".

2) Thermal Control Board

2) Power off and remove the power cord from the

unplugged from the Mother Board

AC entry. Remove the back cover and reseat the

 

Thermal Control Board.

 

 

Front panel displays no text 1) Front panel cable unplugged.

1) Power off and remove the power cord from the

or nothing at all.

AC entry. Remove the back cover and inspect

 

the cable and connectors to and from the front

 

panel. Refer to the "Electrical System

 

Schematic".

40 Electrical Trouble Shooting

User Manual Model 676 LOKPRINT®

Page 46
Image 46
Avery 676 user manual Electrical Trouble Shooting, Power Up / Sign On / Communications