Avery 676 Fuse Configuration, Fuses must be between points a and B as shown not B and C

Models: 676

1 79
Download 79 pages 40.88 Kb
Page 17
Image 17

Fuse Configuration

The main fuse(s) on the AVERY DENNISON 676 LKP are located inside the AC power entry receptacle. The entry has a fuse drawer that holds the fuse(s) and selects the appropriate line voltage. If the number in the window DOES NOT match the AC line intended to be supplied to the printer, DO NOT plug the power cord in. Re configure as follows:

1)Using a flat blade screwdriver, open the AC entry by lifting the tab just above the voltage indicator window.

WARNING: Attempting to open the AC entry with the AC power cord inserted into it will cause damage to the AC entry.

2)Remove the red fuse drawer.

3)Remove all fuses and the fuse jumper if it is present.

4)Insert into the fuse drawer the correct number and style of fuses and fuse jumper for your application.

Configuration Number One:

Line voltage between the range of

 

90 - 132VAC @ 50 - 60Hz 1 Ph

1)Install one 921167 - 10.0A 250V Fast Acting 1/4 x 1 1/4"

2)Install one Fuse Jumper

See Figure FUSE1

Configuration Number Two:

Line voltage between the range of

 

180 - 265VAC @ 50 - 60Hz 1 Ph

1) Install two 921168 10.0A 250V Fast Acting 5 x 20MM

NOTE: The fuse jumper must be removed to install both 5 x 20mm fuses.

The fuses must be between points A and B as shown not B and C.

See Figure FUSE2

FUSE 1

Fuse Jum per

FRONT

Location of115V Text

Location of230V Text

FUSE 2

5 x 20 m m fuse

A

B

C

FRONT

Location of115V Text

Location of230V Text

One 1/4 x 1 1/4" Fuse Far Side

Two 5 x 20MM Fuses One Each Side

5)Reinsert the fuse drawer into the AC entry with the desired voltage up.

6)Close the AC entry and verify the correct voltage is now visible.