Operators Manual

ALS 330/430

6.1 Handling the menu

The menu structure is shown in the following table. By means of the key PRIOR you switch to the prior function, and with the key NEXT to the next following function in the menu.

If you press the key ENTER the current parameter value of a function is shown. The current parameter value can be changed with the keys PRIOR FUNCTION or NEXT FUNCTION. Values are stored by pressing the key ENTER.

Display

Function of the parameter

Possible data entry

DTST

Test run without labels

 

 

 

 

P_S_

Product sensor detects at leading or

LEDG, TEDG

 

trailing edge of product

 

 

 

 

MACH

Machine type

230, 720, 330, 430

 

 

 

MDIR

Motor running direction for left or right

<---- --->

 

hand

 

 

 

 

MLAB

Handling of missing label

NONE, WARN, ERR1, ERR2,

 

 

ERR3

 

 

 

APSF

Automatic product speed follower

YES, NO

 

 

 

APPL

Direct dispense mode, or applicators

DIR, ASA, EP, RVEP

 

 

 

I_CH

Test of inputs

 

 

 

 

O_CH

Test of outputs

 

 

 

 

FACT

Reset of all parameters to default values

YES, NO

 

 

 

BAUD

Baudrate of the interface

NONE, 300 to 192%

 

 

 

PARI

Parity bit

NO, 0PRT, ODD, EVEN

 

 

 

SBIT

Number of Stop bits

1 bit, 2 bit

 

 

 

DBIT

Number of data bits

7 bit, 8 bit

 

 

 

RECY

Recycle (simulates max labels/min)

see text

 

 

 

DIST

Distance label sensor to dispensing edge

10 ... 999 mm

 

 

 

LABC

Number of dispensed labels

see text

 

 

 

QUIT

Return to extended standard menu

 

 

 

 

Release 4/06

Page 44