Operators Manual

ALS 330/430

Message

Meaning

How to solve

 

set to the factory adjustment.

 

E__5

10V supply voltage for label

Short circuit in label sensor or cable.

 

sensor low.

Voltage regulator U14 is damaged.

E__6

24V Voltage low

Short circuit on an output. Total load too

 

 

high i.e. max is 3A for all outputs.

 

 

Voltage regulator U1 is damaged.

 

 

Change main board.

E__7

Material initialization failed

Check if the label web is threaded

 

 

through the label sensor

E__8

Error stepper motor driver

The stepper motor control has detected

 

 

an error. The fault is indicated by the

 

 

LED’s on the driver.

E__9

10V supply for label sensor too

Voltage regulator U14 damaged

 

high

 

E__10

Missing label on product

One or several product could not be

 

 

labelled. Distance between products too

 

 

close. Increase speed of printer.

___0

Process error (Divide overflow)

Hardware failure external noise. EPROM

 

 

damaged. Turn off power and on again.

 

 

Change EPROM or main board

___1

Illegal interrupt (processing error)

Hardware failure external noise. EPROM

 

 

damaged. Turn off power and on again.

 

 

Change EPROM or main board

___2

Illegal bank interrupt (processing

Hardware failure external noise. EPROM

 

error)

damaged. Turn off power and on again.

 

 

Change EPROM or main board

INTO

Illegal interrupt INTP0 (processing

Hardware failure external noise. EPROM

 

error)

damaged. Turn off power and on again.

 

 

Change EPROM or main board.

Release 4/06

Page 74

Errors and warnings

Page 82
Image 82
Avery ALS 330/430 manual Into