Operators Manual

ALS 330/430

8.3.3APSF sensor

For the APSF function (Automatic speed follower) a rotary encoder has to be installed. For optimum labelling accuracy the rotary encoder should be selected so that it produces one pulse for every 0.125 mm of product movement. The connection of the encoder should be done with a shielded cable. For correct operation the rise and fall time of the encoder signal should be

1 µs.

NPN sensor

Supply

Signal

GND

5

9

4

8

3

7

2

6

1

Shield

5

white

9

red

4yellow

1black

+24V

33

27

12

14

GND

CN33

Figure 26 Connection of a NPN type APSF sensor

PNP sensor

 

5

 

Supply

 

9

 

 

4

 

Signal

 

 

 

 

 

8

 

 

 

 

 

 

 

3

 

 

 

 

7

 

 

 

 

2

 

 

 

 

6

 

GND

 

1

 

 

Shield

 

 

 

Figure 27 Connection of a PNP type APSF sensor

 

5

white

 

9

red

4yellow

1black

+24V

33

27

12

14

GND

CN33

Release 4/06

Page 63

Connections and signals

Page 71
Image 71
Avery ALS 330/430 manual Connection of a NPN type Apsf sensor