10

 

Physical Description

AXIS 2420 User’s Manual

Rear Panel

RS-232 Serial Connector

 

 

 

 

I/O-A Connector

 

 

 

A single 9-pin D-sub connec-

Provides the physical interface to a single

tor provides the RS-232 serial

digital photo-coupled input that is used

interface for connecting a

for connecting a variety of external alarm

modem or the AXIS 2191

devices to the AXIS 2420, including tem-

Audio Module. For pinout

perature sensors and switches. In combi-

information, refer to Appen-

nation with the configurable alarm

dix F - The Unit Connectors.

facilities, you can quickly develop a variety

 

 

 

 

 

of security applications that are triggered

 

 

 

 

 

on time- or alarm based- events. The con-

 

 

 

 

 

nector can also be utilized as an alterna-

 

 

 

 

 

tive connection point for DC power to or

Power Supply Connector

 

 

 

 

from the unit. For pinout information, see

 

 

Appendix F - The Unit Connectors.

PS-D connector for connec-

 

 

tion of the AXIS 2420 power

 

 

supply.

 

 

Power Indicator Normally lit when power is applied. If not lit, or if flashing, there is a problem with the camera or with the external power supply.

DC-Iris Connector

Network Indicator

Including full DC-Iris support, any

After completion of the startup

standard DC-Iris lens for outdoor

and self-test routines, this

applications can be fitted.

multi-colored indicator flashes

The connector provides the power

as follows:

 

and control signalling necessary for

• yellow - activity on a

a DC-Iris lens.

10Mbps network

 

• green - activity on a

 

100Mbps network

 

• red - no connection with

 

the network

Network Connector

The AXIS 2420 is designed for 10 Mbps Ethernet and 100 Mbps Fast Ethernet networks and connects to the network via a twisted pair category 5 cable (10baseT and 100baseTX), terminated using

astandard RJ-45 connector. Supporting NWAY, the AXIS 2420 detects the speed of the local network segment and varies the speed of data com- munication accordingly (bet- ween 10 Mbps and 100 Mbps).

Video Out Connector Via a standard BNC connec- tor, this output allows the AXIS 2420 to be connected directly to traditional CCTV systems. It can also be used for adjusting the camera focus in locations where you are unable to view images on a computer screen.

I/O-B Connector

Provides the physical interface for:

1 relay switch output - used for the control of external surveillance devices and ser- vices; e.g. lighting annuncia- tors, audible alarms, etc.

RS-485/422 port for the con- nection of pan tilt devices, etc.

Note: The power supply for your AXIS 2420 is country-specific. Please refer to the Hardware Inventory on page 11 and check that the type of power supply you are using is correct.

Page 10
Image 10
Axis Communications AXIS 2420 Rear Panel, A Connector, DC-Iris Connector Network Indicator, Network Connector, B Connector