axis international marketing 2130R PTZ Operating Environment, Hardware, Pre/Post Alarm Buffer

Models: 2130R PTZ

1 41
Download 41 pages 59.28 Kb
Page 38
Image 38

38

Technical Specifications

AXIS 2130/2130R User’s Manual

Operating Environment

Temperature: +40o to +125oF (0o to +40oC)

Humidity: 20-80% RH non-condensing.

Approved environmental housing required for outdoor use.

Hardware

ARTPEC-1 compression chip

ETRAX 100 LX, 32-bit RISC, 100 MIPS CPU

16MB RAM

4MB FLASH memory.

I/O

1 input and output on a single terminal connector.

Event-triggered actions for remote image storage via FTP or e-mail (SMTP), pre/post alarm image storage.

Pre/Post Alarm Buffer

• Up to 4 MByte memory available for pre/post alarm image storage.

Power

Power supply - 13V DC

Power consumption - max 25W

Approvals - EMC

FCC Class B (DoC)

VCCI Class B

AS/NZS3548 Class B (C-tick)

EN55022/1994, EN50024/1998

EN61000-3-2/1998

EN61000-3-3/1995

Approvals - Safety

• EN60950, UL, CSA (Japan)