axis international marketing 2130R PTZ manual Querying the Status of Digital Inputs

Models: 2130R PTZ

1 41
Download 41 pages 59.28 Kb
Page 36
Image 36

36

The I/O Terminal Block Connector

AXIS 2130/2130R User’s Manual

Example 2: - Set two 300ms pulses with 500ms delay between the pulses on output 1.

http://myserver/axis-cgi/io/output.cgi?action=1:/300\500/300\

Example 3: - Wait 1 second before setting output 1 ON.

http://myserver/axis-cgi/io/output.cgi?action=1:1000/

Digital Input

The digital input is programmed using the Application Wizard, allowing the AXIS 2130/2130R to be configured for time and alarm-based image recording. For example, by connecting a motion detector to the digital input, it is a relatively simple procedure to send a single image (or video stream) to a remote imaging library each time the detector is activated.

Querying the Status of Digital Inputs

The status of the digital input can be queried in exactly the same way as the relay output. Simply enter the following URL to query the status of the digital input:

Example: - Monitor data on input port 1:

http://myserver/axis-cgi/io/input.cgi?check=1

The AXIS 2130/2130R then displays the status of the input, as follows:

Input 1 = 0