Introduction | |
|
|
1.8 Menu System
Press the ENT and ESC keys at the same time to access the Main menu.
The menu system enables the operator to perform such functions as setting up the instrument, viewing logged readings, configuring the four
The buttons on the instrument’s front panel and probe are mapped the same and can be used inter- changeably, with exception of the CAL button.
Select a menu item by first using the Up and Down buttons to highlight the desired item, and then pressing ENT to select that item and display its data screen. After an item has been selected, use the Left, Right, Up, and Down buttons as necessary to highlight and change data within a screen. Pressing the ENT button saves the new data, while pressing the ESC button aborts the operation and displays the previous screen.
Main Menu: |
|
|
|
SYSTEM | System Menu: |
|
|
LOG | GAS TYPE | Gas being monitored | |
SETUPS | LEAK UNITS | Leak rate units of measure | |
CAL DATA | RELAYS | Relay set up for activating external equipment | |
DIAGNOSTICS | LOOP | 4−20 mA signal’s mA per ppm loop factor | |
FACTORY* | BRIGHTNESS | Brightness level of display | |
| CLOCK | Date and time |
|
| PCHK MODE | Determines when a pressure check is performed | |
| PROBE BUTTON | Selects function of button on the Standard Probe | |
| RESET DEFAULTS | Resets user programmable parameters to factory defaults | |
| Log Menu: | (calibration data is not changed) | |
|
|
| |
| VIEW LOG | View individual logged measurements | |
| CLEAR LOG | Clear total contents of log | |
| LOG TOTAL | View a numerical total of all measurements stored in log (up to 50) | |
| LOG LIMIT | Total accumulated leak setpoint | |
| Setup Menu: | SETUP NAME | Text name given to the SETUP selection |
| SETUP NO.1 | RANGE | Sensitivity of instrument (small, medium, large) |
| SETUP NO.2 | GAS TYPE | Gas being monitored |
| SETUP NO.3 | FEEDBACK MODE | |
| SETUP NO.4 | SETPOINT | Gas value for the Feedback Mode & Search Auto |
|
| SEARCH AUTO ZERO .... | Sets condition when auto zero is turned OFF |
| Calibration Data Menu: |
| |
| CAL TYPE | Internal or external leak source | |
| EXT RATE | Leak rate of external leak source | |
| EXT GAS TYPE | Type of gas in external leak source | |
| CAL FACTOR | Calibration factor |
|
| RESTORE FACTORY CAL... Restores factory leak rate calibration (internal leak source only) | ||
| Diagnostic Menu: |
|
|
| SENSOR DATA | Raw data from all sensors | |
| LAST FAULT | List of all current faults, or last fault | |
| IR EMITTER | Infrared emitter’s voltage, amperage, wattage, & resistance | |
| PRESSURE | All measured pressures | |
| Factory Menu: |
|
|
| AUTO GAIN | Automatically set digital potentiometer (zero gas applied) | |
| DIGIPOT | Manually set digital potentiometer (zero gas applied) | |
| LEAK RATE | Leak rate of internal leak source | |
| LEAK GAS | Gas type used in internal leak source | |
| LEAK TEMP | Specified temperature for internal leak source in °C | |
| LEAK TEMPCO | Temperature coefficient for internal leak source in % per °C | |
| SENSOR CAL | Pressure, temperature, and flow calibration settings | |
| MODEL SELECT | Selects model of unit according to part number | |
| PROBE TYPE | Selects type of probe connected to instrument | |
| FIRMWARE | Date firmware was compiled |
* The Factory Menu appears only when activated by service technicians who know the correct activation procedure.