Baldor EXB013A01, Device Net Expansion Board manual FaultRst Set

Models: Device Net Expansion Board EXB013A01

1 54
Download 54 pages 6.04 Kb
Page 40
Image 40

 

Table 6-1

Transaction Specification Table Continued

T#

Name

 

Type

Data Field

Class

Description

 

 

 

 

 

 

 

46

FaultRst

 

Set

BOOL

All

1 = Execute fault

 

 

 

 

 

 

reset

 

 

 

 

 

 

0 = No action

 

 

 

 

 

 

Clears any active

 

 

 

 

 

 

fault condition.

 

 

 

 

 

 

Operation resumes

 

 

 

 

 

 

at previous

 

 

 

 

 

 

command.

 

 

 

 

 

 

 

47

FaultLog

 

Get

C: USINT

All

Requests the

 

 

 

 

FaultLogInde

 

FaultCode and

 

 

 

 

x

 

TimeStamp for the

 

 

 

 

R: UINT

 

given index. The

 

 

 

 

FaultCode,

 

fault log holds the

 

 

 

 

UDINT

 

last 31 fault

 

 

 

 

TimeStamp

 

conditions (1 being

 

 

 

 

 

 

most recent) The log

 

 

 

 

 

 

will return a 0 for the

 

 

 

 

 

 

code and time stamp

 

 

 

 

 

 

if the specified index

 

 

 

 

 

 

is empty. Time

 

 

 

 

 

 

stamp is in seconds.

 

 

 

 

 

 

 

48

FaultCodeText

 

Get

C: USINT

All

Returns the text

 

 

 

 

FaultCode

 

string associated

 

 

 

 

R: STRING

 

with the FaultCode.

 

 

 

 

FaultText

 

16 characters

 

 

 

 

 

 

maximum.

 

 

 

 

 

 

 

49

ForceFault

 

Set

BOOL

All

0->1 =Force Network

 

 

 

 

 

 

Fault

 

 

 

 

 

 

0 = No action

 

 

 

 

 

 

 

50

SecurityStatus

 

Get

USINT

All

Requests network

 

 

 

 

 

 

security status.

 

 

 

 

 

 

0 = Security disabled

 

 

 

 

 

 

1 = Security

 

 

 

 

 

 

unlocked

 

 

 

 

 

 

2 = Security locked

 

 

 

 

 

 

 

* Indicates initial powerup value.