Table 6-1 Transaction Specification Table Continued
T# | Name | Type | Data Field | Class | Description | |
|
|
|
|
|
| |
69 | ClearAll | Set | USINT | All | Reserved for factory | |
|
|
|
|
| use. | |
|
|
|
|
|
| |
70 | LogClear | Set | USINT | All | Reserved for factory | |
|
|
|
|
| use. | |
|
|
|
|
|
| |
71 | AnalogInput1 | Get | UINT | All | Reads the raw value | |
|
|
|
|
| of the A/D | |
|
|
|
|
| converters on the | |
|
|
|
|
| control. Update rate | |
72 | AnalogInput2 | Get | UINT | All | and resolution vary | |
|
|
|
|
| per control. Unused | |
|
|
|
|
| MSBs will be padded | |
|
|
|
|
| with zero. | |
|
|
|
|
|
| |
73 | SetAnalogOut1 | Set | INT | All | Commands the | |
|
|
|
|
| DACs on the control, | |
|
|
|
|
| and/or option card. | |
|
|
|
|
| Analog output | |
|
|
|
|
| parameter must be | |
74 | SetAnalogOut2 | Set | INT | All | ||
set to Serial to be | ||||||
|
|
|
|
| ||
|
|
|
|
| valid. (Note 8 bit | |
|
|
|
|
| DACs will only use | |
|
|
|
|
| the upper byte.) | |
|
|
|
|
|
| |
75 | SetDigitalOut | Set | BYTE | All | Commands the | |
|
|
|
|
| digital outputs on the | |
|
|
|
|
| control, and/or option | |
|
|
|
|
| card. Only lowest | |
|
|
|
|
| four bits are used. | |
|
|
|
|
| The LSB | |
|
|
|
|
| corresponds to opto | |
|
|
|
|
| out #4. The opto | |
|
|
|
|
| output parameter | |
|
|
|
|
| must be set to serial | |
|
|
|
|
| to be valid. | |
|
|
|
|
|
| |
76 | GetDebugVal | Get | C: INT | All | Reserved for factory | |
|
|
| MemLoc |
| use. | |
|
|
| R: INT Value |
|
| |
|
|
|
|
|
|
* Indicates initial powerup value.
Command Language