1 54
Download 54 pages 6.04 Kb
Page 41
Image 41

 

Table 6-1

Transaction Specification Table Continued

T#

Name

 

Type

Data Field

Class

Description

 

 

 

 

 

 

 

51

SecurityLock

 

Set

INT or

All

Unlocks or locks

 

 

 

 

NONE

 

network parameter

 

 

 

 

 

 

security. Passing the

 

 

 

 

 

 

valid SecurityCode

 

 

 

 

 

 

unlocks parameter

 

 

 

 

 

 

access. Any other

 

 

 

 

 

 

value (including

 

 

 

 

 

 

NONE) locks

 

 

 

 

 

 

parameter access.

 

 

 

 

 

 

 

52

CalcPresets

 

Set

BOOL

E,S,V

This transaction is

 

 

 

 

 

 

used during setup to

 

 

 

 

 

 

calculate initial

 

 

 

 

 

 

values for tuning and

 

 

 

 

 

 

performance

 

 

 

 

 

 

parameters based

 

 

 

 

 

 

on motor nameplate

 

 

 

 

 

 

values. Note: this

 

 

 

 

 

 

command is not valid

 

 

 

 

 

 

for all product

 

 

 

 

 

 

classes.

 

 

 

 

 

 

1 = Execute preset

 

 

 

 

 

 

calculation

 

 

 

 

 

 

0 = No action

 

 

 

 

 

 

 

56

BlockStructure

 

Get

USINT

All

Returns the number

 

 

 

 

Level1Max,

 

of blocks on each

 

 

 

 

Level2Max,

 

programming level.

 

 

 

 

Level3Max,

 

Assumes a max of

 

 

 

 

 

 

three programming

 

 

 

 

 

 

levels.

 

 

 

 

 

 

 

57

BlockDetail

 

Get

C: USINT

All

Returns the number

 

 

 

 

Level, Block

 

of parameters in the

 

 

 

 

R: USINT

 

block and the

 

 

 

 

MaxParams,

 

BlockName (16

 

 

 

 

STRING

 

characters max.)

 

 

 

 

BlockName

 

 

 

 

 

 

 

 

 

* Indicates initial powerup value.