Service Mode

SERVICE

IDENTIFICATION

CHANGE PASSWORD CHANGE LANGUAGE CHANGE PROJ. ADDRESS CHANGE BAUDRATE PC RESET LAMP RUNTIME LAMP RUNTINE HISTORY LAMP POWER : 1500W MORE...

Select with or then <ENTER> <EXIT> to return.

SERVICE

PANEL ADJUSTMENTS

PRESET INPUT BALANCE

60Hz TRACKING

I2C DIAGNOSIS

MORE...

Select with or then <ENTER> <EXIT> to return.

PANEL ADJUSTMENT

PRESET INPUT BALANCE

RED COARSE

 

 

 

 

WHITE BALANCE

FIELD FLICKER

 

 

BLACK LEVEL TOP

 

 

BLACK LEVEL BOTTOM

 

 

GAIN TOP

 

 

GAIN BOTTOM

Select with <ENTER>

Change color+pattern

<EXIT> to

return

 

 

with

or

Adjust

Select with

or

red with

or

then <ENTER>

blue with

or

<EXIT> to

return.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I2C DIAGNOSIS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D CA

 

 

 

 

 

 

 

 

 

 

 

 

LCD DRIVER

SC76013

E6H # # #

 

 

 

 

 

 

 

 

 

 

 

 

LCD DRIVER

SC76013

E8H # # #

 

 

 

 

 

 

 

 

 

 

 

 

LCD DRIVER

SC76013

EAH # # #

 

 

 

 

 

 

 

 

 

 

 

 

LCD DRIVER

TDA8444

48H

# # #

 

 

 

 

 

 

 

 

 

 

 

 

INPUT SELECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCF8574A

46H

#

# #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT SELECTOR

 

 

 

 

 

 

 

60 Hz TRACKING

 

 

 

 

PCF8574A

7EH

#

# #

 

 

 

 

 

 

 

 

 

 

 

 

DECODER

PCF8574

4EH # # #

 

 

 

-15

0

+15

 

 

DECODER

SAA7151B 8AH # # #

 

 

 

 

 

DECODER

SAA7152

B2H # # #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DECODER

SAA7192A E0H # # #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP DRIVER

PCF8574A

72H

# # #

 

 

 

 

 

 

 

 

 

 

 

 

POWER SUPPLY 87C752

10H

# # #

Identification

To display the Identification screen, push the control stick forward or backward to highlight Identification and press ENTER to display the Identification screen.

The Identification screen gives an overview of :

-type of projector

-projector address

-software version

-installation configuration

-baud rate

-text ON

-projector serial number

-projector run time

-type of projector : BARCOGRAPHICS 9200

-software version

-Proj. Address : to change the address of the projector, see Change Projector Address in this chapter.

-Installation : possible installations :

*Front/Ceiling

*Front/Table

*Rear/Ceiling

*Rear/Table

To change the installation configuration follow the instructions in chapter Installation Set Up.

-Baud rate : transfer speed for communication with a IBM PC (or compatible) or MAC. The baud rate of the projector must be the same as the baud rate of the connected computer. When there is a difference, consult 'Change Baudrate PC' in this chapter.

-Projector Run Time : gives the total run time since the first start up. All projectors leave the factory with a run time of approximately 24 hours.

-Projector Serial number : indicates the fabrication number of the projector. This number can be useful when calling for technical assistance.

SERVICE

IDENTIFICATION

CHANGE PASSWORD CHANGE LANGUAGE

CHANGE PROJ. ADDRESS CHANGE BAUDRATE PC RESET LAMP RUNTIME LAMP RUNTINE HISTORY

LAMP POWER : 1500W

MORE...

Select with or

then <ENTER>

<EXIT> to return.

11-2

 

5975947 BARCOGRAPHICS 9200 120297

 

Page 42
Image 42