6. Advanced
Important ! In the projectors iD R600 and iD Pro R600 (R9010340 and R9010350) the measuring isdone w ith
white peaking = 0.
Inthe projectors iD R600+ and iD Pro R600+(R9010341 and R9010351) however, the white peaking must be 10
during the measurement.
Thedialogbox shown here are as displayed in the iD R600 and iD Pro R600 (with the field White ).The dialogbox
displayedin the iD R600+ and iD Pro R600+ containthe field White+ instead of White.
The Dynacolor™ InterfaceFollowing parameters are availablein the Dyancolor™ Interface:
Measured Values Theseare the colors the projector displays when no c olorc hanges are made
Red x, y Coördinates forthe Red p oint
Green x, y Coördinates forthe Green point
Bluex, y Coördinates for the Blue point
Whitex, y Coördinates forthe White point
Red L Red Light output
Green L Green Light output
Blue L BlueLight output
WhiteL White Light Output
DesiredValues Theseare the colors you want the projector to display when the status is enabled
Red x, y Coördinates forthe Red p oint
Green x, y Coördinates forthe Green point
Bluex, y Coördinates for the Blue point
Cyan x, y Coördinatesfor the Cyan point
Yellow x , y Coördinatesfor the Yellow point
Magenta x, y Coördinatesfor the Magenta point
Whitex, y Coördinates forthe White point
Red g Red Light Gain
Green g Green Light Gain
Blueg Blue Light Gain
Cyan g CyanLight Gain
Yellow g YellowLight Gain
Magenta g MagentaLight Gain
Whiteg White Light Gain
Status Enablesor disables Dynacolor™
Factory Preset Setsthe measured parameters back to the factory preset for the current set
Basic Dynacolor™ AdjustmentWeassume we have a basic setup with 2 projectors, the Dynacolor™ adjustment is done by using only the Dynacolor™ menu:
1. Enable Dynacolor™ on both projectors.
2. Assume the first projector has the following measured values.
66 R59770134 ID LR-6 27/05/2011