5.0 Automatic Operation

Continuing: Preset Functions

Select function "Preset functions":

Scan Reference Positionj

In the case of a machine malfunction the reference point can be newly scanned with this function.

Procedure:

 

1.

Select "Scan reference position"

< display change >

2.

Confirm "Clear table surface"

< display change >

3.Start backgauge run: Actuate electronical handweel in forward or reverse operation

Abortion of reference run:

Press key

As soon as the reference run has been terminated, the menu "Correct. current position" is displayed.

The displayed basic measurement must be confirmed (see page K5B - 7). After this procedure the Program Data display will automatically be indicated.

Auxiliary operation

If no reference point is found during the reference run an auxiliary mode must be activated (see page K7 - 3)

Possible funtions in Auxiliary mode:

cutting

manual displacement of backgauge by means of of electronic handwheel

K5B - 8