22
5.1.2 MODULE STATUS
By responding to the Enter Selection: message at the end of the Configuration
Main Menu (see Section 5.1.1) with "1" (Module Status), you may review the
current configuration status. The PDI will respond with a menu similar to the
following:
MODULE STATUS
Debounce Delay (Milliseconds)......100
Latch Polarity.....................LO to HI
Reporting Method...................COMMAND
Reporting Start Time...............24:00
Reporting Period...................24:00
Host Address.......................1:1,1
Data Format........................HEX
Time Tagging.......................DISABLED
Terminating Character(s)...........0D0A
Dynamic Configuration..............DISABLED
Press a key to continue or X to Exit.
5.1.3 SAMPLING SETUP
By responding to the Enter Selection: message at the end of the Configuration
Main Menu (see Section 5.1.1) with "2" (Sampling Setup), you may program the
Debounce Delay and Latch Polarity. The PDI will respond with the following
menu:
SAMPLING SETUP
Debounce Delay..................1
Latch Polarity..................2
Exit............................X
Enter Selection:
You may program the Debounce Delay the Latch Polarity from this menu. The
Exit selection will return you to the configuration main menu. For example, if you
type "1" (Debounce Delay), the PDI will respond with the following:
SET DEBOUNCE DELAY
(0-65535 Milliseconds)
Debounce Delay.................100
Exit...........................X
Enter Value<CR>, or X to EXIT: