5.3FRONT PANEL CONFIGURATION

The LCD display and associated front panel controls can provide the configuration status of the PDI. All the parameters shown in the LCD status message are fully described in Section 5.1.

When the M8/M16 DAC has completed its power-up self-test, the following menu will be displayed on the LCD:

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿Bay Technical Assoc ￿

￿ ￿

￿ Select Module ￿

￿ 00 ￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

NOTE: The following LCD screens are examples and will vary depending upon current configuration status.

To review the configuration status of the PDI installed as Module XX (XX = 02 to 16), use the > or ? keys to highlight "Module XX" from the M Series main menu screen and press the SELECT key. The LCD will respond with a menu similar to the following for the PDI-1:

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿V78 PDI-1 MODULE XX￿

￿ ￿

￿Display Status ￿

￿Exit Module Menus ￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Select "Display Status" the LCD will respond with:

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿Debounce Delay 10 ￿

￿Latch Polarity HI/LO ￿

￿Report Method COMMAND￿

￿76-PAGE SELECT-EXIT ￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Pressing the > or ? keys scrolls through the following entries:

Report Interval HH:MM

Host Address 1:1,1

Time Tagging ENABLE

Term Charac ters 0D0A

Dyna Cfg Cmd ENABLE

To exit the configuration status mode, press the SELECT key at any time. You are returned to the PDI's LCD main menu. Next, press either arrow key until the cursor is located on the "Exit Module Menus." Pressing the SELECT button returns you to the main M Series LCD menu.