4.2.2.2 REPORT START TIME

Report Start Time is the time reporting begins when Schedule Reporting Method is selected. The start of reporting may be delayed up to 24 hours from the current time recorded by the M Series time-of-day clock and reporting will occur in cyclic periods as determined by the Report Interval. The default Report Start Time is 00:00.

4.2.2.3 REPORT INTERVAL

You may program the PDI to report in repetitive periods using Schedule Reporting Method, where the PDI will report all event samples in the receive buffer after the specified Report Interval has elapsed. The PDI will report until the buffer is empty and then report again after the specified Report Interval has expired. The default

Report Interval is 00:00 (every 24 hours).

4.2.2.4 HOST ADDRESS

Host Address is the designated host module where event samples are sent when using Immediate or Schedule Reporting Method. The Host Address consists of the Unit Number (1 to 32), Module Number (1 to 16), and Port Number (1 to 4) of the designated host module. The default Host Address is Unit 1, Module 1, Port 1.

4.2.2.5 TIME TAG

When Time Tag is enabled, a time tag is appended immediately after the event sample. The time tag consists of the month, day, year, hour, minute, and second at which the data was calculated. Time Tag may be enabled or disabled. The default Time Tag is disabled.

9

Page 13
Image 13
Bay Technical Associates V79 PDI-1, V80 PDI-2 owner manual Report Start Time, Report Interval, Host Address