20
For example, if the PDI is installed in a non-cascaded unit as Module 2 and you are
using the default port select code ($BT), send $BT2<cr>$CONFIG<cr> to enter
into configuration mode. No characters should be typed between $BT2<cr> and
$CONFIG<cr>. If this happens, the entire configuration sequence will be
discarded and you will have to send the configuration sequence again.
NOTE: All commands must be in uppercase.
To access the menu-driven configuration mode of the PDI from the service port,
use the following procedure:
1. Connect a terminal to the EIA-232 service port and configure the
terminal's serial parameters to 9600 baud rate, 8 word size, 1 stop bit, and
no parity.
2. Connect to the PDI by sending $BAYTECH, the desired module number (2
to 16), and Carriage Return or Line Feed.
3. Access configuration mode by sending $CONFIG<cr>. Following the
example on the previous page, you would send
$BAYTECH2<cr>$CONFIG<cr> to configure Module 2.
NOTE: All commands must be in uppercase.